Frequency; Harmonics; Single / 3-Phase Balanced Powers And Associated Quantities - Chauvin Arnoux F23 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
www.motralec.com / service-commercial@motralec.com / 01.39.97.65.10

5.5 FREQUENCY

Measurement range
Hz
Resolution
Accuracy
Triggering threshold
NB :
Below 0.5 Hz display of 0.00 Hz
If the level of detection is insufficient, display of indeterminate value (- - - -).
Response time of the digital display :
- Normal mode
- SMOOTH mode
5.6 HARMONICS (THD)
Particular reference conditions
- Signal without inter-harmonics whose fundamental is greater than the other harmonic components and the DC
component.
- Min value of the RMS signal 10 V or 10 A
- Fundamental frequency 50 Hz ± 0.05 Hz
- Crest factor of the signal ≤ 5
- Operating range : harmonics of order 1 to 25
Function
Total THD
Total DF

5.7 SINGLE / 3-PHASE BALANCED POWERS AND ASSOCIATED QUANTITIES

Particular reference conditions
Sinusoidal signals : cos ϕ = 1 - Frequency 45...65 Hz
Frequency measurement range : 0.5 Hz to 1 kHz (except on reactive power and DPF : 40...70 Hz)
!
On 3-phase, the measurement is only exact for sinusoidal signals.
Active power (W)
Measurement range
Accuracy
Resolution
NB : The measurement of active power has a ± sign.
Above 600 V/1000 A i.e. 600 kW, the display indicates "OL".
0.50...99.99 Hz
0.01 Hz
0.1% rdg ± 2 counts
f > 20 Hz : 400 ms
f < 20 Hz : ≤ 2 s
f > 20 Hz : 3 s
f < 20 Hz : ≤ 10 s
10...5999 W
1 W
100.0...999.9 Hz
1000...9999 Hz
0.1 Hz
0.2% rdg ± 2 counts 0.5% rdg ± 2 counts
approximately 2 V or 2 A
Measurement range
0.2%...600%
0.2%...100%
6.00...59.99 kW
2% rdg ± 2 counts
10 W
28
10.00...19.99 kHz
1 Hz
10 Hz
Accuracy
1% rdg ± 2 counts
60.0...599.9 kW
100 W

Publicité

Table des Matières
loading

Table des Matières