Agri-Alert 800EZE – Quick Installation Guide
Step 1. Installation
Install the Agri-Alert in a location where a
telephone jack, 120 volt AC power outlet,
and proper grounding connections are
readily available.
Step 2. Wiring
Refer to the wiring diagram overleaf.
(Section 1.3) – Install and connect all zone
sensors and the siren. If the alarm system
uses the phone, connect the phone line
to the Phone Plugin Card and then insert
the card in the PHONE CARD port of the
Agri-Alert. If the system uses an outside
temperature sensor, connect the sensor to
the Outdoor Plugin Card and then insert the
card in the OUTDOOR port of the Agri-Alert.
These 2 plugin cards are optional.
Step 3. Earth Ground
(Section 1.3.9) – Make proper ground
connections. A faulty earth ground
connection immediately voids the system
warranty without further notice.
Step 4. Power Supply
Install the battery and then power up the
Agri-Alert with the 16 VAC wall transformer
(note that the system will not boot when
connecting the battery).
Hierarchy Tree of Controller Menus
Main Menu
Current Conditions
sec. 6.2
View / Modify
Activate / Bypass
sec. 5.5
System Self Test
sec. 3.8.5
System Auxiliaries
Help Menus
sec. 2.2
Install Programming
Step 5. Installation Wizard
Launch the Installation Wizard (sec. 3.1).
Main menu
Install Programming
Use Program Wizard
Below is a list of all programming steps of the
Installation Wizard. Refer to the proper section
of this manual to get information about each
programming step.
- Time & Date (section 3.3)
- Units of measurement (section 3.4)
- Speaker volume (section 3.6)
- Installer Password (section 3.2)
- Setup Zones (section 3.7)
- Phone Numbers (section 4.3 & 4.4)
- Burglar arming options (section 5.4)
- Siren Options (section 3.5)
- Outdoor T° compensation (sec. 5.3)
Step 6. Activating Zones
(Section 3.7.8)
Main menu
Activate/Bypass
Activate Zones
Step 7. Recording Site ID
(Section 3.8.2) Select the menu below to
record the site's identification message.
Update / Backup
ch.10
Password Manage-
sec. 3.2
ment
Event Buffer
sec. 6.3
User Preferences
Software Version
sec. 3.8.6
Change User
sec. 3.2.2
Use Program Wizard
sec. 3.1
Program Zones
sec. 3.7
Program Dialer
sec. 4.3
Program Auxiliaries
Main menu
System Auxiliaries
User Preferences
Voice ID
System Message
Step 8. Phone Call-in
(Section 4.7) – If there is an answering
machine, or fax machine on the same line
as the alarm system, activate the "Share
Phone Line" option. To call the alarm system
from another phone, dial the site number and
allow the site phone to ring only 1 time and
then hang up. Wait 15 seconds and redial
the site number. The Agri-Alert will pick up
the call after the first ring.
Main menu
View / Modify
Phone Call-in
Step 9. System Test
(Section 3.8.5) As a final step, always
perform a system test. A successful test
tells the Agri-Alert is ready to operate. It
is recommanded to perform this test on a
regular basis.
Main menu
Auto-Test
Time & Date
sec. 3.3
Units
sec. 3.4
Voice Volume
sec. 3.6
Voice ID
sec.
3.7.7 &
3.8.2
Zone Settings
sec. 5.5.2
Phone Numbers
sec. 4.4
Auto-Test Schedule
sec. 4.9
Outdoor Probe
sec. 5.3
Output Relays
sec. 3.8.4
Siren Settings
sec. 3.5
Burglar Zone Delays
sec. 5.4.1
Phone Call-in
sec. 4.7
On-Site Listening
sec. 4.6
High Noise Alarm
sec. 3.8.3
Phone Enabled Zones
sec. 4.8
Siren Enabled Zones
sec. 3.7.6
Relay Assigned Zones
sec. 3.7.5
WIRING DIAGRAM
AA800EZE
#891-00441
REV 05
EN