The grounded 3 prong outlet is to be located inside the
cabinet above the range hood at a maximum distance of
33
/
" (85 cm) from where the power cord exits the hood.
7
16
33⁷⁄₁₆" (85 cm)
NOTE: For vented installations, it is recommended that
the vent system be installed before hood is installed.
Before making cutouts, make sure there is proper
clearance within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting
method to use: roof or wall.
2. Select a flat surface for assembling the range hood.
Place covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
3. Using 2 or more people, lift the range hood and set
it upside down onto covered surface.
4. If cabinet has recessed bottom, add wood filler strips
on each side. Install screws to attach filler strips in
locations shown.
3" (7.6 cm)
3" (7.6 cm)
Wall
All manuals and user guides at all-guides.com

INSTALLATION INSTRUCTIONS

Prepare Location

Wood filler strips
(recessed cabinet
bottoms only)
Cabinet
bottom
GROUNDING INSTRUCTIONS
For a grounded, cord-connected range hood:
I
This range hood must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING:
Improper grounding can result in a risk of
electric shock.
Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to
whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
range hood.
SAVE THESE INSTRUCTIONS
Determine Wiring Hole Location
Cut only one 1
/
" (3.2 cm) diameter wiring access hole.
1
4
See Step 2 for wiring hole location instructions.
1. Determine and clearly mark a vertical centerline on the
wall and cabinet in the area the vent opening will be made.
A. Centerline
2. To wire through top:
Mark a line distance "A" from the left of the centerline
on the underside of the cabinet. Mark the point on this
line that is 2" (5.1 cm) from back wall. Drill a 1
diameter hole through the cabinet at this point.
A. 12" (30.5 cm)
A
/
" (3.2 cm)
1
4
2" (5.1 cm)
A
from wall,
not cabinet
frame
Centerline