Télécharger Imprimer la page

Skil 1900 Notice Originale page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
- position the protractor to a corner or
an edge q
- mounting options 7 a, 7 b, 7 c, or
7 d (with screw holes P) can also
be used for setting the protractor on
floors or ceiling
- turn on the tool
- rotate the tool to the desired angle
• Digital levelling
- with the laser beam turned off, the
tool can be used as digital level
- place the tool with the angle
measurement base F on the surface
to be measured w
- alternatively, use magnetic edge E
to attach the tool to a ferrous surface
- the display shows the angle
between the surface and absolute
level
! if the display shows --- the tool is
inclined to forward or backward
too much and the measurement
cannot be made
- to level or plumb the working
surface, move the surface until the
display shows 0º or 90º
- if the deviation is within ±10º of
0° and 90°, fine-tuning arrows are
shown which vary in direction and
height relative to the target e
APPLICATION ADVICE
• Always use the centre of the laser
line for marking (the width of the
laser line changes with the distance)
• Laser viewing glasses 1 (not
standard included)
- laser viewing glasses R 1 filter out
the ambient light
- this makes the light of the laser
appear brighter for the eyes
- do not use the laser viewing
glasses as safety goggles (the
laser viewing glasses are used
for improved visualisation of the
laser beam, but they do not protect
against laser radiation)
- do not use the laser viewing
glasses as sun glasses or in
traffic (the laser viewing glasses do
not afford complete UV protection
and reduce colour perception)
MAINTENANCE / SERVICE
• This tool is not intended for
professional use
• Protect the measuring tool against
moisture and direct sun light
• Do not subject the measuring
tool to extreme temperatures or
variations in temperature (the
accuracy of the measuring tool can
be impaired)
- as an example, do not leave it in
vehicles for long time
- allow the measuring tool to adjust
to the ambient temperature before
putting it into operation
• Avoid heavy impact to or falling
down of the measuring tool
- damage to the measuring tool can
impair its accuracy
• Keep the measuring tool clean at all
times
• Do not immerse the measuring tool in
water or other fluids
• Wipe off debris using a moist and
soft cloth
• Do not use any cleaning agents or
solvents
• Regularly clean the surfaces at the exit
opening of the laser in particular, and
pay attention to any fluff of fibres
• If the tool should fail despite the care
taken in manufacturing and testing
procedures, repair should be carried
out by an after-sales service centre for
SKIL power tools
- send the tool undismantled
together with proof of purchase to
your dealer or the nearest SKIL
service station (addresses as well
as the service diagram of the tool
are listed on www.skil.com)
• Be aware that damage due to overload
or improper handling of the tool will
be excluded from the warranty (for
the SKIL warranty conditions see
www.skil.com or ask your dealer)
ENVIRONMENT
• Do not dispose of electric
tools, batteries, accessories
and packaging together with
household waste material (only for
EU countries)
- in observance of European Directive
8

Publicité

loading