Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

No: 23937 – 06/22 rev. 7
Catalog Number • Numéro de Catalogue • Número de Catálogo: FSP-201
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
DESCRIPTION AND OPERATION
The FSP-201 is a motion sensor that dims lighting from high to low
based on movement. This slim, low-profile sensor is designed for
installation inside the bottom of a light fixture body. The PIR lens
module connects to the FSP-201 through a 1.30" diameter hole in
the bottom of the fixture.
The sensors use passive infrared (PIR) sensing technology that
reacts to changes in infrared energy (moving body heat) within the
coverage area. Once the sensor stops detecting movement and
the time delay elapses, lights will go from high to low mode and
eventually to an OFF position if it is desired. Sensors must directly
"see" motion of a person or moving object to detect them, therefore
careful consideration must be given to sensor luminaire placement
and lens selection. Avoid placing the sensor where obstructions
may block the sensor's line of sight.
The FSP-201 operates at 12–32 VDC. It is designed to be installed
in indoor and outdoor environments.
PIR Sensor
Motion Indicator
Red LED
Sensor Protection Cap
NOTE: Remove Cap before use
Once powering the device up, the FSP-201 will use factory default
parameters to operate. If adjustments are needed, Wattstopper
FSIR-100 Wireless IR Configuration Tool must be used.
Wattstopper
Low Voltage High/Low/Off PIR Fixture Integrated Outdoor Sensor
Basse Tension, Haut/Bas/Éteint
Luminaire avec détecteur IRP extérieur intégré
Bajo Voltaje, Alto/Bajo/Apagado
Sensor PIR para luminarias y uso exterior
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
Voltage ........................................................................12–32 VDC
Current Consumption
Wiring Terminals
Operating Temperature ...................-40°F (-40°C) to 176°F (80°C)
Tightening Nut Torque .................................................25–30 in-lbs
Dimensions
Weight ........................................................................ 2.4 oz (70 g)
Coverage
Adjustments and Features
Light Sensor
IR Transmitter
Factory Defaults
IR Receiver
OPEN DEVICE for installation in a Listed Enclosure per Installation
Instructions.
®
SPECIFICATIONS
Normal Operation .......................................................... 15mA
IR Programming ............................................................ 45mA
Primary Voltage ........................................... +VDC, Com, Ctrl
Control Output ........................................... 100 mA maximum
Dimming Voltage ...........Dim + (purple), Dim - (pink), Ground
Use Solid or Tinned Stranded Copper Conductor
.................................................................... 18AWG–20AWG
Collar ...............................................1.30" diameter (33.0mm)
Collar height ...................................................0.64" (16.3mm)
Body .........1.38" x 3.8" x 0.9" (35.1mm x 96.5mm x 22.9mm)
FSP-L2 Lens @ 8' height ...........................up to 44' diameter
FSP-L3 Lens @ 20' height .........................up to 40' diameter
FSP-L7 Lens @ 40' height .......................up to 100' diameter
High Mode ............................................................. 0 V – 10 V
Low Mode .............................................. . . . . 0 V – 9.8 V, Off
Time Delay ................................. 30 seconds, 1 min – 30 min
Cut Off ............................ Disable, 1 min – 59 min ,1 hr – 5 hr
Sensitivity ............................. On-Fix, Off-Fix, Low, Med, Max
Hold Off Setpoint ............................... Auto, Disable, 1–250 fc
Ramp Up ........................................... Disable, 1 sec – 60 sec
Fade Down ........................................ Disable, 1 sec – 60 sec
Photocell Setpoint for On/Off ..................... Disable, 1–250 fc
High Mode .......................................................................10 V
Low Mode .........................................................................1 V
Time Delay .................................................................... 5 min
Cut Off .............................................................................. 1 hr
Sensitivity ....................................................................... Max
Hold Off Setpoint ....................................................... Disable
Ramp Up .................................................................... Disable
Fade Down ................................................................. Disable
Photocell Setpoint for On/Off ..................................... Disable

Publicité

loading

Sommaire des Matières pour LEGRAND Wattstopper FSP-201

  • Page 1 Wattstopper ® Low Voltage High/Low/Off PIR Fixture Integrated Outdoor Sensor Basse Tension, Haut/Bas/Éteint Luminaire avec détecteur IRP extérieur intégré No: 23937 – 06/22 rev. 7 Bajo Voltaje, Alto/Bajo/Apagado Sensor PIR para luminarias y uso exterior Installation Instructions • Instructions d’Installation • Instrucciones de Instalación Catalog Number •...
  • Page 2 Control Control Common Any 3-Wire Common Any 3-Wire 24VDC 24VDC +24VDC +24VDC Sensor Sensor www.legrand.com • 800.879.8585 www.legrand.us 800.879.8585 0-10V + (Purple) Class 2 16094r1 Class 2 16094r1 wiring only wiring only CTRL (Blue) CTRL (Blue) +VDC (Red) +VDC (Red)
  • Page 3 If still not successful, there may be too much IR interference from 12-32 VDC, 15mA other sources. Programming the unit at night when there is no daylight 800.879.8585 www.legrand.us Appliance Control 88T9 18-20 AWG Solid CU Wire Only 14-18 AWG Solid CU Wire Only available may be the only way to communicate with the sensor.
  • Page 4 Lights will not go into Low Mode: • The time delay can be set from a minimum of 30 seconds to a maximum of 30 minutes. Ensure that the time delay is set to the desired delay and that there is no movement within the sensor’s view for that time period. •...
  • Page 5 INSTRUCTIONS EN FRANÇAIS DESCRIPTION ET FONCTIONNEMENT SPÉCIFICATIONS Le FSP-201 est un détecteur de mouvements qui réduit Tension ................12–32 VCC l'éclairage selon le mouvement. Ce détecteur fin et à profil bas Consommation de courant est conçu pour être installé dans le bas du corps d'un luminaire. Fonctionnement normal ............
  • Page 6 INSTALLATION AVERTISSEMENT COUPEZ L’ALIMENTATION À L’AIDE DU DISJONCTEUR AVANT D’INSTALLER LE CAPTEUR. 1. Déterminez un emplacement de montage approprié à l'intérieur du luminaire qui minimisera la contribution de la lumière électrique à la cellule photovoltaïque du détecteur. FSP-201 Laissez une distance minimale de 5,1 mm (0,2 po) entre l'extrémité...
  • Page 7 Le seul moyen de communiquer avec le détecteur peut être de FSP-201 High/Low PIR Occupancy Sensor programmer l’appareil de nuit, en l’absence de lumière du soleil. 12-32 VDC, 15mA 800.879.8585 www.legrand.us Appliance Control 88T9 18-20 AWG Solid CU Wire Only 14-18 AWG Solid CU Wire Only BOUTONS IR tx/rx Passez d'un champ à...
  • Page 8 • Pour tester rapidement le fonctionnement du dispositif, activez le mode test et sortez de la zone couverte par le détecteur. Les lumières doivent normalement diminuer jusqu’au mode bas au bout de 5 secondes. • Si les lumières ne diminuent toujours pas jusqu’au mode bas, appelez le +1 800 879-8585 pour obtenir une assistance technique. Vérifiez que le fil de charge est solidement fixé: •...
  • Page 9 INSTRUCCIONES EN ESPAÑOL DESCRIPCIÓN Y FUNCIONAMIENTO ESPECIFICACIONES FSP-201 es un sensor de movimiento que regula la luz de alta Voltaje ................12 a 32 V CC a baja según el movimiento. Este sensor delgado de perfil bajo Consumo de corriente está...
  • Page 10 Ground Control Common Any 3-Wire 24VDC Common Any 3-Wire +24VDC 24VDC Sensor +24VDC Sensor www.legrand.us • 800.879.8585 www.legrand.us • 800.879.8585 0-10V + (Violeta) Class 2 16094r1 Class 2 16094r1 wiring only wiring only Control (Azul) Control (Azul) +VCC (Rojo) +VCC (Rojo) Común (Negro)
  • Page 11 High/Low PIR Occupancy Sensor 12-32 VDC, 15mA Si aún no tiene éxito, puede haber un nivel elevado de interferencia infrarroja 800.879.8585 www.legrand.us de otras fuentes. Programar la unidad de noche cuando no hay luz de día Appliance Control 88T9 18-20 AWG Solid CU Wire Only 14-18 AWG Solid CU Wire Only disponible puede ser la única manera de comunicación con el sensor.