No: 26168 – 01/18 rev. 3
Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: PW-311, PW-311-347
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
Models ending in -U are BAA and TAA compliant (Product produced in the U.S.)
The PW Passive Infrared Wall Switch
sensors use advanced passive infrared
(PIR) technology.
1. Make sure that the power has been turned OFF at the circuit breaker.
2. Connect wires to the PW flying leads as shown in the wiring diagram that
is appropriate to the PW model and electrical supply. The ground wire
(green) must be fastened to ground for the sensor to work properly.
3. Attach the sensor to the wall box by inserting screws into the two wide
holes on the top and bottom of the attached metal bracket. Match them
up with the holes in the wall box and tighten. Do not use excessive
force when installing the sensor into the wallbox. Doing so can
bend the mounting strap which can affect button operation.
4. Turn the circuit breaker ON. Wait one minute, then push the Auto ON/
OFF switch and the lights will turn ON. There is a delay due to initial
power-up of the sensor that only occurs during installation.
5. Test and adjust the sensor if necessary.
6. Install industry standard decorator wall switch cover plate (not included).
WARNING: Grounding the violet and gray wires can damage the unit. Do not apply power to
the sensor until all wires are connected or capped off if the driver is to be installed at a future time.
For applications requiring neutral wiring, remove tab
as shown to expose terminals for wiring.
DESCRIPTION
• The PW sensor has Optional Neutral
capability for applications requiring
neutral wiring. It also has Multi-Way
available on all models.
• A "walk-through" mode can turn
lights off after only 3 minutes, if no
activity is detected after 30 seconds
following an occupancy detection.
• The PW-311 has one relay with
dimming control capability and
two buttons to allow control of the
dimming.
• PW sensors contain a light level
sensor. If adequate daylight is
present, the sensor holds the load
OFF until light levels drop, even if
the area is occupied. See the Light
Level Adjustment section.
OPTIONAL NEUTRAL WIRING
Wattstopper
Passive Infrared 0–10 Volt Wall Switch Occupancy Sensor (Version 2)
Interrupteur mural 0–10 Volt avec détecteur de mouvement à infrarouges passif (v2)
Sensor de ocupación con interruptor de pared y tecnología de infrarrojo pasivo de
voltaje 0 a 10 (v2)
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
Voltages:
PW-311 ....................................................120/277 VAC, 50/60 Hz
PW-311-347 ....................................................347 VAC, 50/60 Hz
Load Limits:
@120 VAC ........... 1000-W tungsten ballast, E-ballast, LED, 1/4 HP
@277 VAC ...................... 1200-W ballast, E-ballast, LED, 1/4 HP
@347 VAC ........................................1500W ballast, LED, 1/4 HP
Time Delay Adjustment ..................................................3 to 30 minutes
Walk-Through Mode ....................... 3 minutes if no activity after 30 sec.
Test Mode ............................................. 10 min. with 10-sec. time delay
PIR Adjustment .................................................................... High or Low
Light Level Adjustment .......................................................8fc to 180+fc
Alerts ........................................................Selectable Audible & Visual
Optional Neutral .....................................................................All models
Multi-Way Capability ...............................................................All models
Terminal screw torque ............................................ 16 lbf-in (18 kgf-cm)
High Trim .................................................................................. 6 to 10 V
Low Trim ..................................................................................... 0 to 4 V
Ramp Up ....................................................................... 1 to 10 seconds
Fade Down ................................................................. 2.5 to 30 seconds
INSTALLATION
#12 – #14 AWG
Cu Wire Only
Red
Black
Breakaway
tab
®
SPECIFICATIONS
WARNING: TURN THE POWER OFF AT THE
CIRCUIT BREAKER BEFORE WIRING.
PW-311 and PW-311-347 Wiring
Strip Gage
Yellow
1/2"
12.7mm
Black
Line
Green
Ground
Neutral
8" flying leads for
line, load, ground
and multi-way
connections
Grey
Violet
Yellow
Optional neutral
terminals behind
Green
breakaway tab
0 a 10V
Dimming
Violet
Driver
Gray
or Ballast
Red
White
(optional)

Publicité

Table des Matières
loading

Sommaire des Matières pour LEGRAND Wattstopper PW-311

  • Page 1 Wattstopper ® Passive Infrared 0–10 Volt Wall Switch Occupancy Sensor (Version 2) Interrupteur mural 0–10 Volt avec détecteur de mouvement à infrarouges passif (v2) Sensor de ocupación con interruptor de pared y tecnología de infrarrojo pasivo de No: 26168 – 01/18 rev. 3 voltaje 0 a 10 (v2) Installation Instructions •...
  • Page 2: Button Functions

    MULTI-WAY The Multi-Way capability is available on all models. Sensors can easily Typical Multi-way Wiring be wired together for convenient control of a common load. When wiring (PW-311 or PW-311-347 up to 4 sensors) this way, only use 311 series sensors. Multi-Way in 311 series is not Connect 0-10V Line compatible with prior sensor models.
  • Page 3: Time Delays

    Auto ON With DIP switch 1 in the OFF position, the load turns ON and OFF automatically based on occupancy. There is a 5 second re-trigger delay. If the load is turned OFF manually, the enable/disable setting for Presentation Mode operation applies. See Presentation Mode / Disable Presentation Mode for details.
  • Page 4 Light Level Adjustment This features allows you to set a light level threshold, which determines how the PW-311 will respond based on the ambient light level. This function is available only when the PW-311 is set for Auto ON. There are two modes of Light Level Adjustment. In the Standard mode, you set a fixed threshold. The load will not turn ON automatically until the ambient light drops below that threshold.
  • Page 5: Dip Switch Settings

    DIP SWITCH SETTINGS Time Additional Additional Features Green LED # of Blinks Delay Features Exit Programming Mode Visual Alert 1=OFF, 2=ON Audio Alert 1=ON, 2=OFF Walk-Thru 1=OFF, 2=ON Mode PIR Sensitivity 1=100%, 2=50% Unused High Trim 1=10V, 2=Manual Adjustment Low Trim Mode 1=0V, 2=Manual Adjustment Manual - On...
  • Page 6: Description De L'appareil

    INSTRUCTIONS EN FRANÇAIS DESCRIPTION DE L’APPAREIL CARACTÉRISTIQUES TECHNIQUES Les interrupteurs muraux avec détecteur de mouvement à Tensions : infrarouge passif PW utilisent technologie de pointe pour PW-311 ..............120/277 V c.a., 50/60 Hz l’infrarouge passif (IRP). PW-311-347 .............347 V c.a., 50/60 Hz •...
  • Page 7: Fonctions Des Boutons

    MULTI-VOIES Multi-voies câblage standard La fonction de multi-voies est disponible sur tous les modèles. Les (PW-311 ou PW-311-347, jusqu'à 4 détecteurs) détecteurs peuvent facilement être connectés les uns aux autres pour le contrôle pratique d’une même charge. Si vous effectuez ce type de câblage, Le raccordement utilisez uniquement des détecteurs de la série 311.
  • Page 8: Mode Passage

    jusqu’à ce que plus aucun mouvement ne soit détecté pendant la temporisation sélectionnée. Il existe un délai de re-déclenchement de 30 secondes. Si une présence est détectée pendant ce délai, le détecteur ACTIVE de nouveau la charge. À la fin du délai de re- déclenchement, il est nécessaire d’appuyer sur le bouton Haut pour ACTIVER la charge.
  • Page 9 Délais d’augmentation et de diminution lumineuse Vous pouvez ajuster le délai d’augmentation lumineuse entre le niveau minimum et le niveau maximum lorsqu’un mouvement est détecté ainsi que le délai de diminution lumineuse entre le niveau maximum et le niveau minimum lorsqu’aucun mouvement n’est détecté...
  • Page 10: Réglages Des Interrupteurs Dip

    Mode sans gradation Cette fonctionnalité modifie le fonctionnement des boutons qui deviennent de simples boutons marche / arrêt sans gradation. Le bouton HAUT ACTIVE la charge et le bouton BAS la COUPE. Cette fonctionnalité est désactivée par défaut. Rétablir les paramètres d’usine par défaut Maintenez le bouton Haut ou Bas enfoncé...
  • Page 11: Descripción De La Unidad

    PLAQUES Les interrupteurs muraux de la série PW de WattStopper peuvent être montés derrière des plaques d’interrupteur standard de style Decorator. Les plaques ne sont pas inclus. Les unités sont disponibles dans les couleurs suivantes, indiquées par le suffixe final du numéro de référence (montré ici entre parenthèses): •...
  • Page 12: Funciones Del Botón

    CABLEADO NEUTRAL OPCIONAL Para las aplicaciones que requieren cableado neutral, remueva la lengüeta como se muestra para exponer las terminales para el cableado. Conductores volantes de 8" por línea, conexiones de carga, tierra y de múltiples vías Gris Violeta Rojo Negro Amarillo Terminales neutras...
  • Page 13 AJUSTE DEL SENSOR Y ACCESO A OTRAS FUNCIONES Elimine la placa de la pared. Quite la tapa del botón apretando firmemente Botón de aumento los laterales superiores del botón de ensamble. Con cuidado, retírela de la Botón de atenuación unidad. Cuando se completen los ajustes, vuelva a colocar la tapa del botón insertando sus bisagras en las pestañas de la unidad principal y, luego, apriete la parte superior del botón mientras lo presiona hacia la unidad.
  • Page 14 Recorrido El modo de recorrido acorta el tiempo de demora para reducir la cantidad de tiempo en que la carga está encendida después de un breve momento de ocupación como, por ejemplo, volver a la oficina para buscar algo que se olvidó y salir inmediatamente. Si el modo de recorrido se enciende, el sensor PW apaga la carga tres minutos después de que el área esté...
  • Page 15: Solución De Problemas

    Modo de presentación / Modo de desactivación de presentación El modo de Presentación es una función del modo de Encendido automático. Cuando el relé se apaga manualmente, el PW mantiene las luces apagadas hasta que no se detecta ningún movimiento durante el tiempo de demora. Con la ocupación subsiguiente, el PW enciende la carga.
  • Page 16: Warranty Information

    No. 26168 – 01/18 rev. 3 © Copyright 2018 Legrand All Rights Reserved. 800.879.8585 © Copyright 2018 Tous droits réservés Legrand. www.legrand.us/wattstopper © Copyright 2018 Legrand Todos los derechos reservados.

Table des Matières