Heating; Temperature Rise Phase; Maintaining The Temperature; Maintenance (By A Qualified Technician) - Cillit PoolPAC 6 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

It could be a highly corrosive product that would irreversibly destroy your appliance.

Heating

Temperature rise phase

As soon as you wish to re-start your swimming pool at the beginning of the season, isolate your heat pump from the
filtration circuit:
Close downstream and upstream by-pass valves.
Open setting valve.
Then proceed with all the usual initial operations (water filling, back-wash of the filter...,
Turn the filtration pump on.
Turn pool heat pump on, set temperature, set water flow, open the by-pass valves.
Cover the pool with solar cover or other.
Leave the pool system and pool heat pump working permanently until the pool has reached the required temperature (it
will take approximately 36 hours to 1 week).
Don't forget to set the water flow and required temperatures.
The time for the pool temperature to increase depends on the exposure of swimming pool to wind, sun and the pool
environment as well as the heat pump size.

Maintaining the temperature

Once the set temperature is reached, you may reduce the filtration period according to the temperature requirements (8
to 10 hours a day minimum during the summer). The heat pump will re-start automatically when necessary.
The minimum working time depends of the season; contact your distributor for more information.
If the temperature decreases and the machine work every time the filtration pump is on: increase the filtration time.
A thermal pool cover is very important in order to avoid unnecessary heat loss.
IMPORTANT: An uncovered pool will lose 4 times more heat than a covered pool.
The heat pump working is calculated for a covered swimming pool.

Maintenance (by a qualified technician)

Before any maintenance operation, the heat pump must be completely stopped for few minutes before connecting
pressure controllers. This is because high pressure and temperature inside the heat pump could be harmful.
Please check the following on a monthly basis:
Check and clean the evaporator (with a soft brush or water jet).
Do not use high pressure cleaner.
Check all electrical and ground connections.
Check that all electrical connections and terminals are securely connected.
Check gas pressure (when heat pump is stopped, manometer must indicate a pressure higher than 0.5)
Please check the following points yearly:
Check settings.
Check securities.
Check all electrical connections and ground.
Check condenser cleanliness.
Use soft soap and water to clean the heat pump casing.
Do not use solvents.

After Sales Technical Service

In case of technical problems regarding any of the heat pumps, the following measures should be taken:
Provide to the technical service the following essential information:
Serial number of the machine
Manometer value when machine is stopped
Manometer value when machine is working
The position of ON/OFF button and if it is lit or not
The value and pictograms displayed on digital controller.
The value of programmed settings
If fan is working or not