Controller state table
Screen
Explanation
OFF
Stand-by
No water flow or the flow
FLO
switch
EE3
water flow
Phase error
EE4
(400V machine)
EE6
Comp. Out temp. Too high
EE7
Memory problem
EE8
Communication error.
PP1
Probe error (Water in)
PP3
Probe error (evap.)
(PP10)
PP4
Probe error (comp. in)
(PP11)
PP5
Probe error (ambiance)
PP6
Too much difference between
water in and water out.
(PP8)
PP7
Defrost protection.
HP / HP2
High pressure protection
PP9 / PP12
LP / LP2
Low pressure protection
PP9 / PP10
Check
-
- Verify if water in and outlet are
connected correctly
- Check if filtration pump is working.
doesn't
detect
the
- Check by-pass setting.
- Verify if flow switch is working
correctly
Invert 2 phases from the power
supply.
- Check if filtration pump is working.
- Check by-pass setting.
Change PCB
Check electrical connection between
controller and electronic card inside
the machine.
Check probe connection.
Check by-pass setting.
Ambient temperature was lower than
the
temperature.
- Check by-pass setting.
- Check water flow
- Check if there is gas inside the
machine (manometer between 0,5
and 1,5 when machine is stopped).
- Ambient temperature was lower
than the minimum working range
temperature.
minimum
working
- 26 -
Solution (if no reset)
-
(Contact your seller)
range
- Turn the machine OFF few
minutes.
- Turn the machine ON.
(Contact your seller)