EMC : EN 61326-1
Shock vibration : Sinusoidal vibration per MIL-T- 28800E
(5 ~ 55 Hz, 3g maximum).
Drop Protection : 4 feet drop to hardwood on concrete floor.
Indoor Use.
Electrical Specifications
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C
< 80%RH.
AC Voltage Measurement
Function
Range
100.00mV
ACmV
1000.0mV
10.000V
ACV
100.00V
1000.0V
10.000V
HFR ACV
100.00V
1000.0V
[1] 60Hz to 1kHz
[2] 60Hz to 500Hz
DC voltage Measurement
Function
Range
100.00mV
DCmV
1000.0mV
10.000V
DCV
100.00V
1000.0V
Over voltage protection : 1000V AC rms or DC.
The cut-off frequency of the high frequency reject : 1 kHz.
Input Impedance : 10MΩ // less than 100pF.
Accuracy
50Hz to 60Hz
60Hz to 5kHz
±(0.9%+3d)
±(0.9%+3d)
±(0.9%+3d)
±(0.9%+3d)
±(0.9%+3d)
±(1.9%+3d)
±(0.9%+3d)
±(1.9%+3d)
±(0.9%+3d)
±(1.9%+3d)
±(0.9%+3d)
±(2.9%+3d)
±(0.9%+3d)
±(2.9%+3d)
±(0.9%+3d)
±(2.9%+3d)
Accuracy
±(0.08%+3d)
±(0.08%+2d)
±(0.08%+2d)
±(0.08%+2d)
±(0.08%+2d)
21
[1]
[2]
[2]
[2]

Publicité