Maintenance
Daily:
1. Thoroughly clean back, sides, top and front of unit.
2. Clean trivets daily.
Weekly:
1. Clean unit thoroughly. Clean stainless steel or chromed surfaces with a damp cloth and polish with a soft,
dry cloth. A detergent may be used for cleaning. To remove discolorations, use a non-abrasive cleaner.
2. To clean the drip pan. Remove the drip pan by grabbing the handle and pulling it out of the opening in the
front panel. To replace the pan, reverse this procedure.
3. Burner air shutter openings must be kept clean. Main burner ports must be kept clean. To clean burners,
boil them in a strong solution of lye water for 15 to 20 minutes. Then either brush with a wire brush or clean
gas ports with a sharp-pointed metal instrument to insure open ports.
CAUTION: Clean the regulator at least once a month. Make sure the vent opening is open and not
blocked in any way. Failure to do so will cause variations in pressure. Your unit will not function as well
and it could shorten the life of the product.
SERVICE / REPAIR
NOTE: THIS APPLIANCE MUST ONLY BE SERVICED BY AN AUTHORIZED AGENT.
NOTE: Parts protected by the manufacturer or his agent are not to be adjusted by the installer unless
the installer is an authorized service agent.
If you have any questions or problems contact your nearest Service Representative.
REFERENCE
Item Number
Model Number
43733
CE-CN-HP212M
43734
CE-CN-HP424M
43735
CE-CN-HP636M
Description
Gas Hotplate 2 Burners 12" / 305mm
44,000 BTU ETL
Gas Hotplate 4 Burners 24" / 610mm
88,000 BTU ETL
Gas Hotplate 6 Burners 36" / 914mm
132,000 BTU ETL
12
Manufacturer Model
Number
UR-HP212M
UR-HP424M
UR-HP636M