SILENCER HOUSING MOUNTING INSTRUCTIONS

The 'SCL K-MS' series was designed to provide maximum
flexibility in the positioning of the silencer housings to meet
various installation configurations.
The blower is supplied with the silencers configured as in Fig. 1
If this configuration needs to be modified, proceed as
follows:
1.
Identify the desired configuration (Fig.2, Fig.3, Fig.4).
2. Disassembly of the silencer housing:
2.1 Remove the #906 screws.
2.2 Take away the #700 silencer from the unit along with the
#424 gasket.
3. Disassembly of the #730 blind flange:
3.1 Remove the #909 screws, taking away the #730 flange
along with the #427 gasket.
Reassemble in reverse order-do not forget the #427 gaskets.
162
909
730
427
Fig.1
424
906
700
Fig.2 with 90° manifold
90° manifold
Fig.2
4.1
USING THE 90° MANIFOLD KIT TYPE CK (accessory)
The 90° manifold can only be installed on the #162 cover ports
and as shown in the Figures below, there are multiple
configurations.
The 90° manifold kit type CK comes supplied with;
1 x manifold
1 x #427 gasket and
2 x M8x25 UNI 5739 screws.
To mount the 90° manifold, proceed as follows:
1. Disassemble the silencer housing (see point 2)
2. Place the #427 gasket between the #162 cover and the 90°
manifold and seal with the M8x25 UNI 5739 screws.
Assemble the silencer housing in reverse order-do not forget the
#424 gaskets.
Fig.3 with two 90° manifolds
90° manifolds
Fig.3
GB - 16/38
Fig.4 with 90° manifold
90° manifold
Fig.4