Maintenance and servicing
To guarantee safe working with the product the following checks are necessary:
Regular check of ease of movement of the moving parts (for devices FZ 600 , FZ 900, FZS, FZ500 H and FZ
-
500V) and if necessary lubrication with commercially-available grease.
Take care that no grease gets on to the retaining tongues!
Regular sight and function checks at intervals of max. one year by a qualified person.
-
In the event of damage and particular incidents that could influence the carrying capacity as well as after
-
repairs an extraordinary testing by a qualified person is to be carried out.
As proof that the tests have been carried out, a test list is to be compiled by the operator.
Declaration of conformity
Herewith we, the DENIOS AG, Dehmer Straße 58-66, D 32549 Bad Oeynhausen, declare that the product complies
with following guidelines.
Type:
Safe working load:
EC Directives
Machinery directive 2006/42/EC
Harmonised standards applied
EN 13155
EN 349
EN ISO 14121
EN 12100 -1,-2
Person responsible for documentation
Mr. Dr. Ing. R. Adenstedt
Head of engineering
Fasshebegeräte
115256, 115261, 115266, 164399,
164397, 115188, 115187, 164400, 164641
EC Declaration of Conformity
Drum tongs
FZ 600, FZ 900, FZ-S, FZ 500 H, FZ 500 V
Lifting gear
FGV, FGH
Drum gripper
P 500, P 360
350 kg
Seite 9 von 16 Seiten