Window Function „Opener"
Opener:
Window:
Delay time:
Analog Output
Operation
Switch On and Off
The device is switched on after the electrical power is connected. „u01" is
displayed during initialisation. Then the is-value will be displayed.
Attention!
The programmed pressure unit (bar / PSI / MPa) is not displayed. You should
check the programmed pressure unit when receiving unexpected measurements,
before you suspect an error in the pressure system.
© Hydrotechnik GmbH
Conf = nCLS
Func = FEn
dSP1 = 00.00 / drS1 = 00.00
The output contact is opened when
the pressure is between the two
thresholds. This is valid for incre-
asing and decreasing pressure.
Thresholds: SP1 = 250 / rSP1 =
200
The set measuring range of the analog
output is (example)
(Fro = 0)
to
(to = 400)
at
(AnA0 = 0 to 20) mA
or (4 to 20) mA.
E
29