I N S TA L L AT I O N

Installation

DO NOT CONNECT AC SUPPLY TO TERMINALS MARKED "TRIAC CONTROL."
Triac Control feature is not supported.
S T E P 1
Connect AC supply
Use conduit or NM type cable as appropriate.
Note: Acceptable wire is both solid core and stranded. Gauge range is 2.59 Ø[mm]/5.26 Ø[mm2] -
1.29 Ø[mm]/1.31 Ø[mm2].
Open appropriate terminals by flipping orange levers into UP position (see fig. 7). Make connections to
1.
the "AC Mains In" section connecting to appropriate line, neutral and ground terminals.
Note: Wire strip length is 0.47 in (12 mm).
Insert appropriate conductors from Mains Power (see fig. 8).
2.
Black conductor goes to "L" terminal (Black).
White conductor goes to "N" terminal (White).
Green conductor goes to "
Note: Conductor colors are not always as listed. These colors vary depending on your wiring setup.
To ensure the correct wiring, consult a professional electrician.
fig. 7
continued on next page
P/N 3662351 Rev B
© 2019 Ketra, Inc. All rights reserved.
" terminal (Green).
fig. 8
9 | N3 INSTALLATION GUIDE