Connection and operation
Error handling
Torch cooling fault
Cooling fault is indicated on machines in case of
insufficiant circulation of the cooling liquid due to
faulty connection, defective parts or choking. Check
that the cooling hoses are correctly connected, top up
the water tank and check welding hose and branches.
The cooling fault is cancelled by pressing shortly on
P
the
-key pad.
Gas control fault (IGC)
Gas fault exists due to a to low or high gas flow.
Make sure that the pressure on the gas flow is higher
than 2 bar and less than 6 bar, corresponding to higher
than 5 l/min and less than 27 l/min.
The fault is disconnected by adjusting the manual
gas flow to 27 l/min. The gas fault is reset by a short
P
pressure on the
-key pad.
Technical data
Duty cycle 100% 40°C, A
Duty cycle 60% 40°C, A
Duty cycle max. 40°C, A/%
Wire feed speed, m/min
Torch connection
Wire diameter, mm
Gas pressure max., MPa (bar)
Touch Sense max. voltage, V
Touch Sense max. current, mA
Compressed air max., MPa (bar)
Dimensions (HxWxL), mm
Standards
Weight, kg
1
Protection class
Equipment marked IP23 is designed for indoor and outdoor
1)
applications.
All manuals and user guides at all-guides.com
Software
In case of exchange of the control PCB, software must
be reloaded, using an SD card. Latest software can be
downloaded at www.migatronic.com
Save the software on an SD card containing the folders
and one or more of the files shown below.
To order SD card, use item no 78861297.
430
550
0.5-30.0
Software update
EURO
• Insert the SD-card
0.6-1.6
• Turn on the machine
• Wait until the unit
0.6 (6.0)
indicates that the update
100
is complete
100
• Turn off the machine and
0.8 (8.0)
remove the SD card
240x220x308
• The machine is now ready
for use
IEC60974-5.
IEC60974-10 CL. A
6.8
IP23
MIGA_SW
SIGMA
10003664.cry
(control software package)
9