microHAM ARCO Mode D'emploi page 46

Table des Matières

Publicité

Create: RC5x
Rotator tab settings:
PARAMETER
VALUE
SENSOR
POT 1 kΩ or 5 kΩ
MOTOR
AC+CAP
POWER
24 V
BRAKE
NO
TOTAL ROTATION 370
LIMIT SWITCHES
YES
Create une connexion de potentiomètre
inversée tout au long du cycle de production. Si vous obtenez l'erreur "AUCUN MOUVEMENT",
échangez les extrémités du POT sur les broches 1 et 3.
TIC General: 1022, 1032, 1048
Rotator tab settings:
PARAMETER
VALUE
SENSOR
POT 500 Ω
MOTOR
DC (reversible)
POWER
24 V
BRAKE
NO
TOTAL ROTATION 400
LIMIT SWITCHES
NO
M2 Antenna Systems: OR2800G2
Rotator tab settings:
PARAMETER
VALUE
SENSOR
REED
P/360º
3960
MOTOR
DC (reversible)
POWER
48 V
BRAKE
NO
TOTAL ROTATION 388
LIMIT SWITCHES
YES
microHAM © 2021 All rights reserved
OTHER
Rotator connection:
ROTATOR
WIRE
COM
CW
CCW
POT HI
WIPER
POT LO
LS
Rotator connection:
ROTATOR
WIRE
CW
CCW
POT HI
WIPER
POT LO
Rotator connection:
ROTATOR
WIRE
CW
CCW
REED B
REED A
46
ARCO
PIN
NAME
1
MOTOR D + LSW CCW
2
MOTOR A
3
MOTOR C
4
SENSOR HI
5
SENSOR C
6
SENSOR LO
7
LSW CW
ARCO
PIN
NAME
2
MOTOR A + B
3
MOTOR C + D
4
SENSOR HI
5
SENSOR C
6
SENSOR LO
ARCO
PIN
NAME
1
MOTOR A + B
2
MOTOR C + D
3
SENSOR LO
4
SENSOR C + HI
PIN
5 + 8
6
4
3
2
1
9
PIN
6 + 7
4 + 5
3
2
1
PIN
6 + 7
4 + 5
1
2 + 3

Publicité