TAPER: CD-44, HAM xx, T2xx
Rotator tab settings:
PARAMETER
VALUE
SENSOR
RHEO 500 Ω
MOTOR
AC
POWER
24 V
BRAKE
YES / (NO for CD-44)
TOTAL ROTATION 360
LIMIT SWITCHES
YES
TAPER: AR-40(X)
Rotator tab settings:
PARAMETER
VALUE
SENSOR
RHEO 1 kΩ
MOTOR
AC
POWER
24 V
BRAKE
NO
TOTAL ROTATION 360
LIMIT SWITCHES
NO
TAPER: HDR-300A
Rotator tab settings:
PARAMETER
VALUE
SENSOR
POT 1 kΩ
MOTOR
AC+CAP
POWER
24 V
BRAKE
YES
TOTAL ROTATION 400
LIMIT SWITCHES
YES
microHAM © 2021 All rights reserved
HY-GAIN (CDE)
Rotator connection:
ROTATOR
WIRE
COM/WIPER
BRAKE
POT HI
CCW
LS CW
LS CCW
CW
* Add supplied 330Ω resistor in series for improved
accuracy in first CCW quarter circle. Optional adapter
already includes series resistor.
Rotator connection:
ROTATOR
WIRE
POT LO
WIPER
COM
CCW
CW
Rotator connection:
ROTATOR
WIRE
CW
CCW
COM
BRAKE
POT HI
WIPER
POT LO
45
ARCO
PIN
NAME
1
MOTOR D + SENSOR LO 5 + 1
2
MOTOR B
3
SENSOR HI
4
MOTOR C
5
LSW CW
6
LSW CCW
8
MOTOR A
ARCO
PIN
NAME
1
SENSOR LO
2
SENSOR HI
3
MOTOR D
4
MOTOR C
5
MOTOR A
ARCO
PIN
NAME
1
MOTOR A
2
MOTOR C
3
MOTOR D
4
MOTOR B
5 (8)
SENSOR HI
6 (9)
SENSOR C
7 (10) SENSOR LO
PIN
7
3*
4
9
8
6
PIN
1
3
5
4
6
PIN
6
4
5
7
3
2
1