READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Models L100, L150, L200, L250, and L300 only:
If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or shower.
10. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further information
and requirements.
COOKING AREA
Do not install above or
o
45
NOT FOR USE IN
A COOKING AREA.
LOSONE SELECT
Ceiling/Wall Mount
inside this area.
o
45
Cooking
Equipment
Floor
VENTILATORS
®
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
ROUND DUCT*
ADDITIONAL
1½" FRAMING
Blower factory-shipped
in horizontal
discharge position.
GRILLE
(Polymeric
shown)
Install after
ceiling is
finished.
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
2 X 4 FRAMING
(wide side down)
ROUND DUCT*
CEILING JOIST
(16" centers
shown)
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing & up-
side-down,
so housing is
flush with
finished ceiling)
GRILLE
(Polymeric shown)
Factory-shipped unit installed in existing construction.
* L100 & L150 Series uses 6" Round Duct.
1
L200, L250, & L300 Series uses 8" Round Duct.
Mounting brackets
factory-shipped in
position for ½" ceil-
ing material.
CEILING JOIST
(16" centers shown)
MOUNTING
SCREW
GRILLE
SCREW
FINISHED
CEILING
MATERIAL
GRILLE
SCREW

Publicité

loading

Sommaire des Matières pour Broan LOSONE SELECT

  • Page 1 LOSONE SELECT VENTILATORS ® Ceiling/Wall Mount READ AND SAVE THESE INSTRUCTIONS WARNING TYPICAL INSTALLATION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY MOUNTING (New Frame Construction) TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If...
  • Page 2 TYPICAL INSTALLATION MOUNTING OPTIONS WIRING ¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position. BLACK TOP / BACK BLACK 1½" OF HOUSING " MAX. 2½" GROUND TO WIRING PLATE 12¼"...
  • Page 3 DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling. Motor is permanently lubricated. Do not oil or disassemble motor. VENTILADORES LOSONE SELECT ® Para montaje en cielo raso/pared LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA 4.
  • Page 4 ÁREA QUE COCINA CUIDADO No instale sobre o dentro de esta área. 1. Para uso de ventilación general solamente. No lo use para extraer materiales o vapores peligrosos o explosivos. 2. Para evitar daño a los cojinetes del motor y hélices ruidosas y/o desequilibradas, mantenga la unidad de potencia lejos de rocíos de yeso, polvo de construcción, etc.
  • Page 5 OPCIONES PARA LA COLOCACIÓN DE IMPORTANTE: Quite la cinta del envío de apagador CONDUCTOS Asegúrese de quitar la cinta que fija la pestaña del regulador durante POSICIONES DE LA DESCARGA DEL VENTILADOR la transportación, y de que esta pestaña abra y cierre libremente dentro del conducto.
  • Page 6 VENTILATEURS LOSONE SELECT ® Montage au plafond/mur LIRE ET CONSERVER CES INSTRUCTIONS INSTALLATION TYPIQUE AVERTISSEMENT MONTAGE (Construction en cours) POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES PERSONNELLES, OBSERVEZ CE QUI SUIT: 1. Utilisez cette unité seulement de la façon prévue par le fabricant.
  • Page 7 OPTIONS DE MONTAGE INSTALLATION TYPIQUE CÂBLAGE Des écrous à six pans ¼-20 fixent les supports au boîtier. Desserrer et resserrer ou retirer et replacer les écrous si nécessaire, selon la position désirée pour le support. NOIR AU DESSUS / AR- NOIR RIÈRE DU BOÎTIER 1½"...
  • Page 8 OPTIONS D’INSTALLATION DES CONDUITS UTILISATION ET ENTRETIEN Le ventilateur a été conçu pour une utilisation continue. Si désiré, il POSITIONS DE LA DÉCHARGE DE LA SOUFFLERIE peut être commandé à l’aide d’un interrupteur marche/arrêt ou d’un régulateur de vitesse à semi-conducteurs. Suivre les instructions de RACCORD câblage fournies avec le régulateur et respecter tous les codes locaux et provinciaux en vigueur, de même que le Code national de l’électricité...

Ce manuel est également adapté pour:

Losone select l100 serieLosone select l150 serieLosone select l200 serieLosone select l250 serieLosone select l300 serieLosone select l100l ... Afficher tout