LOSONE SELECT
In-Line • 120V
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to mini-
mize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 3.
®
VENTILATORS
®
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "TYPICAL INSTALLATION"
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (straight-through blower discharge)
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
-Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (right angle blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
• "WARRANTY"
MODELS
L400L • L500L • L700L
Page 1
Page 1
99042725E

Publicité

loading

Sommaire des Matières pour Broan LOSONE SELECT L400L

  • Page 1 MODELS L400L • L500L • L700L ® Page 1 Page 1 LOSONE SELECT VENTILATORS ® In-Line • 120V READ AND SAVE THESE INSTRUCTIONS WARNING TABLE OF CONTENTS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- This manual is divided into sections as follows: JURY TO PERSONS, OBSERVE THE FOLLOWING: •...
  • Page 2 MODELS L400L • L500L • L700L ® Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) WIRING Mounting brackets 10” (254 mm) BLACK 4½” (114.3 mm) X factory-shipped in 18½” (469.9 mm) ROUND DUCT position for ½” BLACK TOP / BACK TO 10”...
  • Page 3 MODELS L400L • L500L • L700L ® Page 3 MOUNTING OPTIONS DUCTING OPTIONS BLOWER DISCHARGE POSITIONS ¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position. DUCT CONNECTOR DUCT CONNECTOR 1½"...
  • Page 4 THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 5 MODÈLES MODELS L400L • L500L • L700L ® Page 5 VENTILATEURS LOSONE SELECT ® Montage au plafond/mur • 120 V LIRE ET CONSERVER CES INSTRUCTIONS AVERTISSEMENT TABLE DES MATIÈRES POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC Ce manuel se divise comme suit : ÉLECTRIQUE OU DE BLESSURES PERSONNELLES, OBSERVEZ CE QUI SUIT: •...
  • Page 6 MODÈLES L400L • L500L • L700L ® Page 6 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) CÂBLAGE CONDUIT TRANSITION NOIR AU DESSUS / CIRCULAIRE 4½ X 18½ au 10 po NOIR ARRIÈRE DU DE 10 po (254 mm) Supports (114.3 x 469.9 au BOÎTIER préassemblés pour...
  • Page 7 MODÈLES MODELS L400L • L500L • L700L ® Page 7 OPTIONS D’INSTALLATION DES CONDUITS OPTIONS DE MONTAGE Des écrous à six pans ¼-20 fixent les supports au boîtier. Desserrer POSITIONS DE LA DÉCHARGE DE LA SOUFFLERIE et resserrer ou retirer et replacer les écrous si nécessaire, selon la RACCORD DE CONDUIT RACCORD DE CONDUIT position désirée pour le support.
  • Page 8 Pour le service sous garantie, vous devez (a) aviser Broan-NuTone Canada á l’adresse ou au numéro de téléphone ci-dessous, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout défaut dans le produit ou la pièce. Au temps de demander le service sous garantie, vous devez présenter une preuve de la date d’achat original.

Ce manuel est également adapté pour:

Losone select l500lLosone select l700l