Actionneur électromécanique 24vdc pour portes sectionnelles et basculantes à ressort jusqu'à 2,25 m de haut et basculantes à contrepoids jusqu'à 2,45 m, surface maximum 8 m2
5 5 . . R R e e m m o o t t e e c c o o n n t t r r o o l l b b u u t t t t o o n n s s e e l l e e c c t t i i o o n n ( ( d d e e f f a a u u l l t t : : 2 2 ) )
This menu allows selection of the button to be used for controlling the automation system. This function may be useful where it is desired
to control several different automation systems using different buttons on the same remote control.
5
+
-
Press the
key,
5 5
the display shows
5
+
Press the
key to save the
settings: the display shows
6 6 . . O O p p e e n n a a l l a a r r m m ( ( d d e e f f a a u u l l t t : : 0 0 – – f f u u n n c c t t i i o o n n d d e e a a c c t t i i v v a a t t e e d d ) )
If this function is activated, the device emits BEEPs for 30 seconds when the door remains open for longer than 10 minutes. The alarm is
repeated every 10 minutes. Close to door to interrupt the alarm.