Télécharger Imprimer la page

EUCHNER HBA Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Hand-Held Pendant Stations HBA/HBM
Technical data, general
Parameter
Housing material
- Hand-held pendant station HBA
- Hand-held pendant station HBM
Color
- Hand-held pendant station HBA
Gray RAL 7040/black RAL 9004
- Hand-held pendant station HBM
Weight
Depending on version
Operating temperature
0 °C ... +50 °C
Storage temperature
-20 °C ... +50 °C
Atmospheric humidity, max.
80% (condensation not
Front degree of protection
Acc. to EN 60529 / IEC 529
Acc. to NEMA
Resistance to vibration
Vibrations (3 axes)
DIN EN 60068-2-6
Shock (3 axes)
DIN EN 60068-2-6
EMC protection requirements
acc. to CE
Technical data of components
EMERGENCY STOP
Standard
Switching elements
Max. 2 NC contacts
Utilization category
acc. to IEC 60947-5-1
U
e
B
10D
Enabling switch ZXE
Standard
Switching elements
Utilization category
acc. to EN 60947-5-2
U
=24 V / I
e
B
10D
Pushbuttons
Switching element
1 x NO contact
Switching voltage, max.
Switching current, max.
Breaking capacity, max.
Membrane keypad
Switching elements
Normally open contact
Switching voltage, max.
AC 25 V/DC 42 V
Switching current, max.
Selector switches
Switching code
1 of X, Gray, hex
(see connection diagram)
Switching voltage, max.
Breaking capacity, max.
Other components
See EUCHNER catalog for hand-held pendant stations or
www.euchner.com
Technical data for handwheel
See operating instructions for the related handwheel.
Accessories
See EUCHNER catalog for hand-held pendant sta-
tions or www.euchner.com.
Value
Polycarbonate
PBT-PC
Anthracite
permissible)
IP65
250-12
EN 61000-6-2
EN 61000-6-4
Value
EN ISO 13850
DC-13
=24 V / I
= 3 A
e
0.1 x 10
6
Value
EN 60947-5-8
2 NO contacts
DC-13
= 0.1 A
e
0.75 x 10
6
Value
DC 30 V
0.1 A
1 VA
Value
0.1 A
Value
25 V
0.2 VA
4

Publicité