deep discharged. Please see section DESCRIPTION OF FUNCTIONS for details.
The default low voltage disconnect (LVD) setting is Mode 1- Disconnect at 11.4V
(at nominal load current) up to 11.9V (at no load current).
Menu 3: Nightlight function (type)
In this menu, you can set the type of nightlight function or switch off the nightlight
function of your CXN controller.
The default setting of nightlight function type is OFF.
Menu 4: Nightlight function (evening settings)
When the nightlight function type is set to EVENING/MORNING mode, you can
set the load ON hours after sunset in this menu.
The default load ON hours after sunset is 0 hr.
Menu 5: Nightlight function (morning settings)
When the nightlight function type is set to EVENING/MORNING mode, you can
set the load ON hours before sunrise in this menu.
The default load ON hours before sunrise is 0 hr.
Menu 6: Day/Night threshold
In this menu, you can set the open circuit voltage of PV panel that the CXN
controller should know it's day or night.
The default day/night threshold is 4.9V for 12V PV system(9.8V for 24V PV system).
Menu 7: Buzzer on/off
You can turn ON/ turn OFF the buzzer in this menu.
38