Operation
Display
Status-LEDs
 
 
  
 
  
 LED off;
LC-Display
When contacting with the finger, observe the reference to the
earthing potential. This means that incorrect indication of the
LC display can occur if the person carrying out, has insufficient
contact with the earthing potential (e.g. wooden ladder, thick
rubber soles etc.).
20
OK
L<>N
L
N
PE
L<>PE
L<>PE&PE
L<>N& N
LED on
Warning!
OK, Phase on the right side
Phase on the left side (OK)
Phase missing
Neutral missing, Phase on the
right side
Ground missing
Phase/Ground inverted
Phase/Ground inverted and
Ground missing
Phase/Neutral inverted and
Neutral missing
Voltage at PE