SPECIFICATIONS
Installation Requirements
The cup warming drawer can be installed in a standard or
flush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
An anti-tip block must be installed to prevent the cup
warming drawer from tipping forward when opened.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Cup Warming Drawer
TRIM OVERLAP
Top
Bottom
Sides
COMBINATION INSTALLATION
To install a cup warming drawer below a coffee system,
one opening for both units must be specified. To achieve
the minimum reveal between units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
Installation of an anti-tip block is not necessary when the
cup warming drawer is installed below a coffee system.
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on
the following pages. A separate circuit, servicing only this
appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Power Cord
Connection of this appliance should be
IMPORTANT NOTE:
through a fused connection unit or a suitable isolator, which
MIN
complies with national and local safety regulations. The
34 kg
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
0 mm
installation (depending on country) an additional means of
0 mm
disconnection must be provided for all poles of the power
18 mm
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
RATING
PLATE
Rating plate location.
Cup Warming Drawer
STANDARD INSTALLATION
220-240 VAC, 50/60 Hz
420W
.9 m
ANTI-TIP BLOCK
SIDE VIEW
NOTE: Dashed line represents profile of unit.
572 mm
OPENING
DEPTH
TOP VIEW
140 mm
E
OPENING HEIGHT
562 mm
OPENING WIDTH
FRONT VIEW
|
wolfappliance.com
3