BAW M12MI-BLC35C-S04G and BAW M12MH-BLC70G-S04G
Inductive Linear Position Sensor
6
IO-Link interface (continued)
6.5
System parameters
Index
Parameters
Hex. Dec.
000D 13
Profile characteristic
000E 14
PDInput descriptor
Tab. 6-6:
System parameters
6.6
Sensor-specific parameters
Index
Parameters
Hex. Dec.
0052 82
Temperature array
Internal temperature
Max. temperature startup 02
Min. temperature startup
Max. temperature lifetime 04
Min. temperature lifetime
0056 86
COMx speed
0057 87
Number of startups
0058 88
Operating hours
00C0 192
Gradient
00C1 193
Offset
00C5 197
Inversion
00C8 200
Slmin[μm]
Slmax[μm]
Note that the floating point values are coded as little-endian, so LSB comes first.
1)
2)
For BAW M12MI-BLC35C-S04G
For BAW M12MH-BLC70G-S04G
3)
Tab. 6-7:
Sensor-specific parameters
12
english
Subindex
Parameters
Hex. Dec.
01
1
DeviceProfileID
02
2
FunctionClassID
04
4
FunctionClassID
05
5
FunctionClassID
01
1
BDC1,BDC2, BDC3
02
2
PDV1
03
3
PDV2
Subindex
Data format
(length)
Hex. Dec.
00
0
Char (5 bytes)
01
1
Char (1 byte)
2
Char (1 byte)
03
3
Char (1 byte)
4
Char (1 byte)
05
5
Char (1 byte)
00
0
Char (1 byte)
00
0
UINT32 (4 bytes)
00
0
UINT32 (4 bytes)
00
0
Float32
(4 bytes) Read only
1)
00
0
Float32
(4 bytes) Read only
1)
00
0
UChar (1 byte)
01
1
UINT16 (2 bytes)
02
2
UINT16 (2 bytes)
Data format
Access
UINT16
Read only
OctetStringT3 Read only
Access
Value range Comments
Read only
–128...+127
Read only
2
Read only
Read only
Read/Write 0x00-0x01
Read/Write 200...3500
2)
200...7000
3)
Read/Write 200...3500
2)
200...7000
3)
Comments
Smart sensor profile
Binary data channel
Process value
Teach channel
Switching channel
OutOfRange
Position value
Output of all
temperature
parameters (in °C)
IO-Link COM speed
Gradient of curve
(output → distance)
Curve offset
(output → distance)
Curve inversion
Current value for
Slmin[μm]
Current value for
Slmax[μm]