Sommaire des Matières pour Balluff BES M12MG2-GNX20B-S04G-X04
Page 1
BES M12MG2-GNX20B-S04G-X04 english User’s guide français Notice d’utilisation...
Page 2
Instruction manual BES M12MG2-GNX20B-S04G-X04 Instruction manual Inductive Sensor BES M12MG2-GNX20B-S04G-X04 Order Code: BES05TY Intended use The inductive proximity switch is for use as contactless wearout-free limit switch in industrial control systems. The inductive proximity switch may only be connected to electronic evaluation devices type BAE SA-XE- XR-SA39.
Instruction manual BES M12MG2-GNX20B-S04G-X04 Technical data Certificate number CSA 20CA80041978X HazLoc marking Class I, Division 1, Groups A, B, C, D T6...T3 Class II, Division 1, Groups E, F, G, T80°C Class III, Division 1 Ex ia IIC T6…T3 Ga Ex ia IIIC T80°C Da Class I, Zone 0, AEx ia IIC T6…T3 Ga Zone 20, AEx ia IIIC T80°C Da Temperature range EPL Ga and Class I, Division 1: – 20 °C ≤ Ta ≤ +60 °C – 20 °C ≤ Ta ≤ +60 °C – 20 °C ≤ Ta ≤ +60 °C – 20 °C ≤ Ta ≤ +60 °C EPL Gb and Class I, Division 1: – 25 °C ≤ Ta ≤ +75 °C – 25 °C ≤ Ta ≤ +75 °C – 25 °C ≤ Ta ≤ +75 °C – 25 °C ≤ Ta ≤ +75 °C EPL Da and Class II, Division 1: – 25 °C ≤ Ta ≤ +75 °C EPL Db and Class III, Division 1: – 25 °C ≤ Ta ≤ +75 °C Maximum value Ui 9.6 V DC Maximum value Ii 12.1 mA Maximum value Pi...
Instruction manual BES M12MG2-GNX20B-S04G-X04 Trouble shooting Failure Cause of failure Remedy The functioning indicator does not light Supply voltage too low or Check power supply up in the electronic evaluation devices not connected when the proximity switch is actuated The display “CHK” lights up in the...
Mode d’emploi BES M12MG2-GNX20B-S04G-X04 Mode d’emploi Capteur inductif BES M12MG2-GNX20B-S04G-X04 Code de commande: BES05TY Utilisation conforme à l’usage prévu Dans le cadre de processus de pilotage industriels, le détecteur de proximité inductif sert de détecteur de fin de course sans contact et sans usure. Il peut uniquement être relié à des modules électroniques d’analyse type BAE SA-XE- *** -XR-SA39.
Mode d’emploi BES M12MG2-GNX20B-S04G-X04 Caractéristiques techniques Numéro d’certificat CSA 20CA80041978X HazLoc marquage Class I, Division 1, Groups A, B, C, D T6…T3 Class II, Division 1, Groups E, F, G, T80°C Class III, Division 1 Ex ia IIC T6…T3 Ga Ex ia IIIC T80°C Da Class I, Zone 0, AEx ia IIC T6…T3 Ga Zone 20, AEx ia IIIC T80°C Da Plage de température EPL Ga and Class I, Division 1 : –20 °C ≤ Ta ≤ +60 °C –20 °C ≤ Ta ≤ +60 °C –20 °C ≤ Ta ≤ +60 °C –20 °C ≤ Ta ≤ +60 °C EPL Gb and Class I, Division 1 : –25 °C ≤ Ta ≤ +75 °C –25 °C ≤ Ta ≤ +75 °C –25 °C ≤ Ta ≤ +75 °C –25 °C ≤ Ta ≤ +75 °C EPL Da and Class II, Division 1 : –25 °C ≤ Ta ≤ +75 °C EPL Db and Class III, Division 1 : –25 °C ≤ Ta ≤ +75 °C Valeur maximale Ui 9,6 V DC Valeur maximale Ii...
Mode d’emploi BES M12MG2-GNX20B-S04G-X04 Dimensions M12x1 Schéma de raccordement Zone non exposée à un risque d‘explosion Zone exposée à un risque d‘explosion Tension de service BAE SA-XE- (1) BN capteur à sécurité intrinsèque ***-XR-SA39 certifié, conformément à (2) WH IEC 60947-5-6 –...
Mode d’emploi BES M12MG2-GNX20B-S04G-X04 Recherche d’erreurs Erreur Cause de l’erreur Solution Lors de l’actionnement du détecteur de Aucune ou trop faible Vérifier la tension proximité, aucun indicateur de fonction tension d’alimentation d’alimentation ne clignote sur l’analyseur L’affichage d’erreurs sur l’analyseur Court-circuit ou rupture du Vérifiez que le câble de clignote câble de raccordement raccordement soit exempt de défauts Pas de modification du signal de Utilisation du détecteur de...
Page 10
US Service Center CN Service Center Germany Germany China Balluff GmbH Balluff GmbH Balluff Inc. Balluff (Shanghai) trading Co., ltd. Schurwaldstrasse 9 Schurwaldstrasse 9 8125 Holton Drive Room 1006, Pujian Rd. 145. 73765 Neuhausen a.d.F. 73765 Neuhausen a.d.F. Florence, KY 41042 Shanghai, 200127, P.R.