3
EN - Installation instructions
3.1
Safety instructions
WARNING
Important instructions for commissioning!
Observe all instructions; incorrect installation can result in serious injuries.
NOTE
Original language and translations
The original language of this document is German. All other languages are
translations.
•
Use the safety strip evaluator TST SURA-6 only with controllers from
FEIG ELECTRONIC GmbH!
•
Read the installation manual of the used controller and be sure to observe the
safety instructions for the controller.
•
These installation instructions must be available to the service personnel at all
times.
•
The installation and replacement of accessories may only be carried out by
qualified personnel.
•
The manufacturer has carefully checked the device hardware and software as
well as the product documentation. Mistakes cannot be avoided completely
and we will always gratefully accept any information in this respect.
Dispose of the product at the end of its service life in accordance
with the valid legal specifications.
3.2
Abbreviations and definitions
Abb./Fig.
Figure
Tab.
Table
Gate and barrier controller with integrated frequency
Controller (TST)
converter or reversing contactor for triggering a motor.
The qualified specialist have been informed concerning
possible dangers in case of improper behaviour by working
with electrical equipment. The qualified specialist is familiar
Qualified
with the necessary protective measures and devices.
specialists
Furthermore, through the specialists professional training
and experience as well as its contemporary professional
activity, the specialist has the necessary knowledge for
testing work equipment.
Controller
TST SURA6
TST_SURA6_Install_rev10_mul
3.3
Product specification
The TST SURA-6is an accessory of the company FEIG ELECTRONIC GmbH with
the following characteristics:
•
All functions are adjustable by parameter via the controller.
•
Monitoring of an 8,2 kΩ resistor for short circuit, interruption, correct value
range.
•
Grouping into 2 x 3 inputs, i.e. a common output signal is generated from
three input signals each, which is described in the controllers as "external
safety evaluations".
3.3.1
Intended use
The plug-in module is a safety strip evaluator with testing for the direct connection
of a maximum of six safety strips with 8.2 KΩ terminating resistor. The plug-in
module can be used optionally.
Operation is only permitted with the following controllers:
CE
TST FUF2-A,-C, -F Series
TST FU3F-AU, -CU, -FU, -RU Series
TST FU3F-A,-C, -F Series
TST FU3H-FU Series
TST FUH2-C Series
TST FU3H-F Series
TST FUZ2-B, -C Series
TST FUZ2-CX, -L, -P, -S Series
3.4
Technical data for Europe
Dimensions (LxWxH)
70 x 60 x 15 mm
Operation
-20 °C to +70°C
Temperature
Storage
-25 °C to +85°C
Weight
34 g
Equipment type
Plug-in module, safety strip evaluator
Protection type
IP 00
Protection class
--
Supply voltage
24 VDC ±20%
Power consumption
max. 2 W
Current carrying capacity
--
Connection/interface
X81/X82: 2 x MOLEX socket, 5-pin
X85: external safety edge input
Battery
--
Other
4 LEDs for displaying the input states of the
connected safety edge
3 | 6
Strip input Short circuit
Strip input Interruption
Strip input OK
Connection
X83 (831-832)
X84 (841-842)
X85 (851-851)
X86 (861-862)
X87 (871-872)
X88 (881-882)
3.5
UL-Ratings
UL
Supply
Class 2 output
Maximum surrounding air
temperature
Degree of pollution
Battery
Connection description
NOTE
the safety strip evaluator TST SURA-6 is only intended to be located in Class 2
circuits and is only intended for installation inside the FEIG ELECTRONIC
Power Conversion Equipment, series TST.
Connection
X83 (831-832)
X84 (841-842)
X85 (851-851)
X86 (861-862)
X87 (871-872)
X88 (881-882)
FEIG ELECTRONIC GmbH
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
info@feig.de
Inputs
0 Ω < Resistance of strip < 4.1 Ω
16,4 kΩ < Resistance of strip < kΩ
4.1 Ω < Resistance of strip < 16.4 Ω
Cable size
Tightening
flexible with wire
torque
rigid
end ferrule
0.35 – 0.4 Nm
2
2
0.2-2.5 mm
0.25 - 1.5 mm
24 VDC ±20%
--
85 °C
For use in an environment with pollution
degree 2.
--
X83-X85: 3x input 12 V/type. 1,6 mA
X86-X88: 3x input 12 V/typ. 1.6 mA
Tightening
Cable size
NEC wiring
torque
24 - 14 AWG
5 Lb-in
Class 2
2
(0.2 - 2.1 mm
)
(0.4 Nm)
2019-10-14