Wiring of the power cable for the PowerCon
connector (supplied with the unit).
The power cord assembly must be made by a qualified technician in
compliance with the national regulations in force for electrical systems.
Strip the cable for 20 mm of length and strip each wire for 8 mm of
length. We suggest to use a power cable with 2,5 mm
wires (the insert terminals can however support a cable with wires up
to a section of 4 mm
2
/12AWG).
Insert the power cable into the bushing and into the chuck (white
chuck for a cable diameter of 5 ÷ 11 mm; black chuck for a cable
diameter of 9.50 ÷ 15 mm). Insert the wires into the terminals and
fasten the clamping device with a flat-blade screwdriver.
The wire ends can be clamped in or soldered to the terminal, always
paying attention to the symbols shown on the connector:
L
(Live - corresponding to the brown wire),
N
(Neutral - corresponding to the blue wire) and
(Ground - corresponding to the yellow-green wire).
Once the wires have been connected to the insert, lead the cable
through the housing and screw down the bushing by means of a 3/4"
fork wrench (min. torque 2.5 Nm / 1.8 lb-ft).
The cable must comply with the applicable, country specific, safety
regulations.
The minimum conductor size must be: 2.5 mm
cable wired to the NC3 MPA (AC line in) plug and 1.5 mm
for the cable wired to the NC3 MPB (AC loop out) plug.
The mains power plug on the other end of the cable must be certified
for a current equal to 20A at least (eg: IEC309 32A).
When, for any reason, the power cable show signs of damage, it is
mandatory to replace or repair it before any further use.
To replace the cable:
1 - disconnect the cable at both ends
2 - unscrew the bushing (3/4" wrench)
3 - using a screwdriver, disconnect all three conductors from the insert
4 - remove the chuck and the bushing from the cable
5 - using a new cable, complying with the previous reported require-
ments, proceed with the connector's assembly, as described above.
CAUTION:
- Before plugging and/or unplugging the PowerCon connector, it is
mandatory to switch off all the equipment that is connected to the
cable and to disconnect the cable from AC mains.
- Follow this procedure also when the speakers must be moved.
Operate as illustrated in the side drawing when you have to plug
and/or unplug the connector.
active subwoofer
®
section
2
(13 AWG) for the
2
2
(15 AWG)
20 mm
8 mm
wires
wires
cable
chuck
insert
inside view
housing
Plugging
cable
bushing
setscrews
®
power con
connector
Unplugging
ENGLISH
15

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Tank12sa

Table des Matières