Control and connection panel

8
7
1 X-OVER (24dB / 12dB) switch allowing the selection of the X-Over
slope. The X-Over frequency, is always set to 100 Hz. The filter is a
Linkwitz-Riley type.
Button up: the slope is at 24dB/oct.
Button down: the slope is at 12dB/oct.
2 X-OVER: balanced XLR male sockets for the stereo cross-over output.
3 IN: balanced XLR inputs for the connection to the mixer.
4 LINK: balanced XLR male sockets ('link') for parallel connection of
active speaker systems.
 See 'connectors' and 'connection examples'.
5 VOLUME: input level control. Allows to set the input sensitivity of the
built-in power amplifier. Turning this control fully clockwise (to its
maximum setting) sets the input sensitivity to +3dBu (stereo), 9dBu
(mono).
6 PHASE REVERSE: by means of this switch the absolute phase of the
subwoofer may be reversed, allowing for the use of satellite loudspeak-
ers with a non-standard phasing, or for multi-subwoofer installation,
thereby avoiding possible phase cancellations.
 See 'Phase' on page 17.
4
3
LINK
IN
L
LINK
IN
R
AC LOOP OUT
AC LINE IN
IMAX 15A
230V
50-60Hz 5A
active subwoofer
2
X-OVER
X-OVER
POWER
I
0
Internal Fuse
7 AC LINE IN: mains supply inlet socket with type A PowerCon ® (blue)
connector, which guarantees a reliable, vibration-proof contact.
Use only a mains cable with suitable conductors capable of handling
the current involved, equipped with a ground conductor, marked with
the applicable, country specific, safety approvals and fitted with a
power plug certified for the actual current value.
Refer to page 14 for connector wiring instructions.
When installing make sure that it is easy to get to this socket and to
the mains plug.
8 Power 'AC LOOP OUT' socket (type B gray PowerCon ® connector)
that allows you to link other devices to the mains power (max. current
available: 15A).
CAUTION: the power supply PowerCon® socket (7) is rated for a 20 A
maximum current. The maximum current that may be sourced from the
'AC LOOP OUT' socket is 15A.
If the 'AC LOOP OUT' socket is used to supply power to other devices,
it is the user's responsibility to verify that:
- this maximum current drain is not exceeded,
- the power cord assembly is made by a qualified technician in
compliance with the national regulations in force for electrical
systems.
9 Mains power switch.
5
6
VOL.
P HA S E
180°
X-OVER
X-O V ER 1 0 0H z
24dB/oct
12dB/oct
1
9
12
ENGLISH