Caution
In case of DC supply, a protection diode needs to be installed. No instructions for an electric strike or
an electro-magnetic lock should prevent you from using this protection. Generally, 1N4004 or 1N4007
diodes are used.
The product warranty does not cover misuse or abusive use of the product as well as accidents, bad
maintenance or inappropriate surroundings.
SETTING
The receiver can work both with the standalone mode or the web mode. These two are not exclusive,
which means for example that you can start with it in standalone mode (by using master remotes
and user remotes) and then switch to the web mode by adding extra remotes when an encoder is
purchased.
Setting of the switches
Some dipswitches (see diagram above) are designed to setup the apb feature of the receiver.
The following chart shows the functions of those dipswitches:
Please note that dipswitches S4 and S5 are linked to the setting of S3. For example:
If S4 is off when S3 is on, the anti-passback function is permanent.
S1 Operating mode
S2 Unused
S3 without Apb
S4 Apb 24/7
S5 Apb on entry only
S6 PB1 (push button 1) - Relay 1/ PB2 - Relay 2 PB3 - Relay 1 / PB4 - Relay 2
Programming of the door release time:
The factory setting for the door release time is 3 seconds. However, it is possible to modify these
values as follows:
Move the S1 switch to on. S2 and S3 have to be off.
Press the RTE button 1 as many times as the wished number of seconds in order to program the door
release time. Do the same for relay number 2.
At any time, it's also possible to change the door release time in remote management mode by crea-
ting configuration remote control.
DOC.50-001-450.C
Off
FDI MATELEC SA Route de St Symphorien 85130 Les landes Génusson - France
On
Programming mode
Unused
Apb active
Anti-pass time
Apb on entry + exit
www.fdimatelec.com
11