Télécharger Imprimer la page

RAIS/attika R-600 Notice D'installation page 89

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 99
REMOVING THE COMBUSTION CHAMBER LINING
REMOVING THE COMBUSTION CHAMBER LINING
The combustion chamber lining protects the body of the
fireplace insert from the heat from the fire. The large differences
in temperature can lead to cracks in the combustion chamber
lining. This will not affect the functionality of the fireplace insert.
The lining will only need be replaced after several years of use
when it begins to disintegrate.
The liner panels are simply placed in position by hand and can
easily be replaced by you or your dealer.
Procedure to remove the combustion chamber lining:
1.
Remove the flue panel (1) by pushing the front up and pulling
forward, so that the rear end becomes free of the vertical
panels. The flue panel can now be carefully removed.
2.
Remove the base panel (2).
3.
Loosen the side panels by turning the end of the panel in towards
the fireplace's centre. Next, carefully remove.
4.
Remove the rear panels (4) by removing the lock in the top of
the panels. The panels are now loose and can be removed.
5.
Panels (5) and (6) are located under the turbo plate and are not
normally removed.
3
2
2
5
1
4
4
3
6
EN - 23