a) Connection – LOOPbACK
1. To connect, you will need the Western reduction insert RJ-45/R-J11 (23) and the TAE adaptor
(RJ-11-TAE).
2. Insert the reduction insert into the RJ-45 jack mAIN and the RJ-45 jack LOOPbACK. Align the
inserts' connector guide edges to those of the RJ45 jacks.
3. Connect the TAE jack on the telephone cable to the TAE jack on the TAE adaptor (25). Connect
one cable end to the RJ-45 jack mAIN and the other to the RJ-45 jack LOOPbACK.
The remote test port is not needed to test telephone cables.
b) Conducting a test
1. Turn on the cable tester and push the TeL button. Or select "2. TEL MODE" using the navigation
buttons and confirm with the TesT button.
2. Use the navigation buttons (up, down) to select the number of conductors:
- "2C" (two conductors), "4C" (four conductors), "6C" (six conductors)
3. Push the TesT button to begin testing. The test result can be read on the display. See Ill. 2.
- By negative reading "FAIL": the conductors in question blink on the display.
- In case of "CROSS": the conductors in question are shown blinking in their current position.
- In case of "SHORT": the conductors in question blink.