Problem
The coffee
machine
produces less
coffee than
before.
I cannot close
the lid properly.
Solution
Switch off the machine. Pull up the lever as far as it
goes and wait 24 hours before you open the lid. You
may need to use quite some force.
Make sure that the sieve in the centre of the pod
holder is not clogged. If it is, unclog the sieve by
holding the pod holder under a running tap. If
necessary, you can use a washing-up brush to unclog
the sieve.
Make sure you do not move the SENSEO
Moving the machine, placing it outdoors or in a
cool or cold environment does not accelerate the
unlocking of the lid.
Do nOt put the SENSEO
or freezer, as this does not accelerate the unlocking
of the lid.
If problems continue to occur, contact the Philips
Consumer Care Centre in your country.
Perhaps the sieve in the centre of the pod holder is
clogged. If this is the case, unclog the sieve by rinsing
the pod holder under a running tap. Use a washing-
up brush to clean the sieve, if necessary.
Descale the machine (see chapter 'Descaling').
Check if a used coffee pod is sticking to the water
distribution disc. If this is the case, remove the
used pod.
Check if you used the correct pod holder. Use 2
pods in combination with the deeper 2-cup pod
holder qq. Use 1 pod in combination with the
1-cup pod holder q.
EnglisH
®
machine in the fridge
®
27
machine.