Operation Instruction
Search
Parameter
Parameter Name
Code
Settable
F00
parameter entry
Search for indoor
F03
unit engineering
code and location
Search for
F05
number of online
indoor units
Ambient
F08
temperature of an
indoor unit
Ambient
F11
temperature of an
outdoor unit
Unit Parameter Setting
Press and hold the "
display area of the wired controller will display the searchable parameter code "F00". Then,
press and hold the "
parameter setting interface and the temperature display area will show a flashing "A00".
Press the "▲" or "▼" button to select the parameter to set and then press the "
The timer area displays the parameter value to set and flashes. You can press the "▲" or
"▼" button to change the parameter and finally, press the "
setting and return to the previous menu.
Parameter
Range
-
1.The Timer area displays the current indoor unit
engineering code.
2. Location of a faulty indoor unit: Press the "
1~16
to access the location of an indoor unit. The buzzer of
the associated indoor unit will sound for 2 seconds.
Press the "
buzzer of the current indoor unit will stop.
1~16
-30 to 90
-30 to 90
" button on the wired controller for 5 seconds. The temperature
" button on the wired controller again for 5 seconds to enter the
15
View Mode
" button to exit location menu. The
" button to complete the
" button
" button.