Problem and alarm code
The temperature of the water inside
the appliance is too high or malfunc‐
tion of the temperature sensor oc‐
curred.
• The indicator
times intermittently.
• Acoustic signal sounds 6 times
intermittently.
Technical malfunction of the appli‐
ance.
• The indicator
times intermittently.
• Acoustic signal sounds 12 times
intermittently.
The level of water inside the appli‐
ance is too high.
• The indicator
times intermittently.
• Acoustic signal sounds 15 times
intermittently.
The appliance stops and starts
more times during operation.
The programme lasts too long.
Small leak from the appliance door.
The appliance door is difficult to
close.
Rattling/knocking sounds from in‐
side the appliance.
The appliance trips the circuit-beak‐
er.
Possible cause and solution
• Make sure that the temperature of the inlet
water does not exceed 60°C.
• Switch the appliance off and on.
flashes 6
• Switch the appliance off and on.
flashes 12
• Switch the appliance off and on.
• Make sure that the filters are clean.
• Make sure that the outlet hose is installed at
flashes 15
the right height above the floor. Refer to the
installation instructions.
• It is normal. It provides optimal cleaning re‐
sults and energy savings.
• If the delayed start option is set, cancel the
delay setting or wait for the end of the
countdown.
• The appliance is not levelled. Loosen or
tighten the adjustable feet (if applicable).
• The appliance door is not centred on the
tub. Adjust the rear foot (if applicable).
• The appliance is not levelled. Loosen or
tighten the adjustable feet (if applicable).
• Parts of the tableware are protruding from
the baskets.
• The tableware is not properly arranged in
the baskets. Refer to basket loading leaflet.
• Make sure that the spray arms can rotate
freely.
• The amperage is insufficient to supply si‐
multaneously all the appliances in use.
Check the socket amperage and the capaci‐
ty of the meter or turn off one of the applian‐
ces in use.
• Internal electrical fault of the appliance.
Contact an Authorised Service Centre.