Specifications
Product
Dimensions
Temperature sensor models
In cold condition, a temperature of 10 °C is output; in switched condition, the max. temperature of 200 °C is output.
1)
EIB 521x: as opposed to other variants, a temperature of 250 °C is output in switched condition.
2)
Electrical data
DC supply voltage from
PELV
Typical current consumption
at a supply voltage of 5 V
60
EIB 5181: approx. 165 mm x 31 mm x 107 .2 mm (with top hat rail: 118 mm)
EIB 521x: approx. 64 mm x 98 mm x 38.5 mm
EIB 528x: approx. 64 mm x 98 mm x 38.5 mm
KTY 84-130
PT1000
PTC
1) 2)
PTC triplet
1) 2)
Three KTY 84-130 sensors with a common reference
EIB 5181: 4.5 V to 5.5 V
EIB 521x: 3.6 V to 14 V
EIB 528x: 4.5 V to 5.5 V
Sensor value
EIB 5181
3x 33 Ω
58 mA
3x 75 Ω
57 mA
3x 500 Ω
54 mA
3x 1000 Ω
52 mA
Open
43 mA
EIB 5211
EIB 5212
EIB 5281
35 mA
43 mA
43 mA
35 mA
43 mA
42 mA
33 mA
41 mA
40 mA
31 mA
35 mA
38 mA
24 mA
24 mA
30 mA
HEIDENHAIN | EIB 5000 | Operating Instructions | 11/2020
EIB 5282
51 mA
50 mA
48 mA
42 mA
30 mA

Publicité