Temperature: ≤ 200 °C= valid temperature values
Temperature : ≥ 220 °C= general fault
Reaction
Temp
= 220.0 °C
max
Temp
= 220.0 °C
max
Temp
= 240.0 °C
max
1)
Note: PTC/PTC triplet: no detection possible because terminating resistance is also high-impedance
EIB 5181
Temperature: -15 °C ... 200 °C = valid temperature values
If the temperature value is exceeded or fallen below, the value is limited and the status LED is activated
The status LEDs light up in case of a sensor error or invalid configuration.
5181", Page 54
Reaction
Temp
= 220.0 °C
max
Temp
= 220.0 °C
max
Temp
= 240.0 °C
max
Note: PTC/PTC triplet: no detection possible because terminating resistance is also high-impedance
1)
58
Fault condition
Fault
R
 30.0 
Sensor short
Sensor
≥ 6500.0 
Sensor wire break-
R
1)
Sensor
age
Invalid configuration
Fault condition
Fault
R
 30.0 
Sensor short
Sensor
≥ 6500.0 
R
Sensor wire break-
1)
Sensor
age
Invalid configuration
Corrective action
Check the sensor and sensor connection.
Exchange, if necessary
Check the sensor and sensor connection;
exchange, if necessary
Contact HEIDENHAIN
Further information:
Corrective action
Check the sensor and sensor connection;
exchange, if necessary
Check the sensor and sensor connection;
exchange, if necessary
Contact HEIDENHAIN