IMPORTANT SAFETY INSTRUCTIONS
DANGER
A person who has not read and
understood all operating
Instructions is not qualified to
operate this product.
DANGER
Do not immerse end seal in liquid.
Keep volatile or combustible material away from
end seal when in use.
Use end seal only in approved locations.
Keep sharp metal objects away from end seal.
Failure to observe these warnings may result in electric
shock, risk of fire, and personal injury.
WARNING
End-User Must Comply to the Following:
Only qualified personnel are allowed to connect electrical wiring.
Disconnect all supply power at the source before making any power connections.
All electrical wiring must follow local electrical codes and highly recommend following NEC Article 427.
The person who performs the final installation / wiring must be qualified for this work.
The end-user is responsible for providing a suitable disconnecting device.
The end-user is responsible for providing suitable electrical protection device. It is highly recommended that a
ground fault circuit breaker be used.
Failure to observe these warnings may result in personal injury or damage to the product and/or property.
®
© BriskHeat
Corporation. All rights reserved.
SLCBLKC End Seal Kit
Installation Instructions
Agency Approvals
Approvals valid only when installed in accordance with
all applicable instructions, codes, and regulations.
CAUTION
Inspect all components before use.
Do not use end seal kit if any component is
damaged.
Do not repair damaged or faulty components.
Do not crush or apply severe physical stress on
any component of system.
Unit must be mounted away from vibration,
impacts, water and corrosive gases.
Do not operate above rated temperature value.
Fasten end seal using approved methods only.
Failure to observe these warnings may result in personal
injury or damage to the product and/or property.
3
PRODUCT OVERVIEW
Description
The SLCBLKC End Seal Kit is suitable for use only with the SLCBL series self-regulating heating cable.
The kit contains materials for end seal connections. This kit does not provide a power connection: use a
SLCBLUC or SLCBLUC-GF power connection kit for a complete installation.
Applications
Use the SLCBLKC kit with the following heating cables: SLCBL-B, SLCBL-BP and SLCBL-BF. SLCBL-B
is designed for pipe freeze protection in dry locations. SLCBL-BP cable is designed for both wet and dry
locations, as well as for roof and gutter de-icing. SLCBL-BF cable is designed for both wet and dry
locations, as well as strong chemical environments. The cable type is printed on the outer jacket of the
cable.
Tools Required
Scissors, Flat nose pliers, Needle Nose Pliers, Utility Knife, Cutters, Heat Gun
Required for each end seal connection
Item
Qty
Description
Heat Shrink Tube, 5" L x 3/4"D
A
1
(13cm x 2cm)
Woven Braid Sleeve, 4"L x 1/2"D
B
1
(10cm x 1cm)
C
1
Heat-Shrink Cap 1/2"D (1cm)
Note: Additional Accessories May Be Required.
WARNING:
ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heating cable and
accessories. A qualified person must perform installation and service of heating cable and accessories.
Heating cable must be effectively grounded in accordance with the National Electrical Code. Failure to
comply can result in personal injury and/or property damage.
Note:
All electrical wiring, including Ground Fault Protection must be installed according to National Electrical
or local codes by a qualified person.
Article 426 of ANSI/NFPA 70 of National Electrical Code (NEC Section 62 of CAN/CSA-C22.1 Canadian
Electrical Code, Part I (CEC)) governs the installation of this heat system.
SLCBLKC End Seal Kit is suitable for use with SLCBL series heating cables.
Keep ends of heating devices and kit components dry before and during installation.
®
© BriskHeat
Corporation. All rights reserved.
SLCBLKC End Seal Kit
Installation Instructions
A
B
C
4