Pump does not
switch off
Insufficient water
Pump does not
start or suddenly
switches off while
functioning
Pump suddenly
provides less
water
Guarantee
The submersible pump you have purchased comes with the usual guarantee which
applies to production and material defects. The following damage and defects are
not covered by the guarantee:
 Wear and tear and defects in relation to mechanical seals caused by drying out
or the presence of specific substances and/or objects in the water.
 Blockage of the blade by foreign objects
 Transport damage
 Damage caused by unreasonable use
 Defects that unauthorised persons have attempted to resolve or which have
been caused by improper repairs
 Damage due to overheating
The guarantee and liability of the supplier, importer and manufacturer will be
nullified if the pump is opened by unauthorised persons or modifications or
additions are made to the pump.
Float cannot sink
-
Inlet openings are
-
(partially) blocked
Too little pumping
-
capacity due to
contamination and dirty
water
Thermal safeguard stops
-
pump due to overheating
Water is too hot
-
Power outage
-
Dirt or stones in the
-
water supply
Suction openings are
-
blocked
Hose is blocked
-
Give the float more space
-
Clean them
-
Clean the pump and replace
-
worn out parts
See: overheating safeguard
-
Max. water temperature 35°C
-
Check fuses and earth
-
leakage
Remove dirt and stones
-
Clean the openings
-
Clean it
-