Installation
1. Remove the two screws (A1) from the fitting template (A),
then remove the template, see fold-out page I, fig. [1].
2.Turn the valve stem (B) clockwise to the OFF position.
3. Make sure the water supply is turned on at the service
stop valves (C). Stop valves must be in fully open position
(slots horizontal) for valve to function.
4. The adjustable hot water limit stop (D) is factory set at
neutral position to give maximum outlet temperature, see
fig. [2] and [5].
Please refer to chapter "Maximum hot water limit setting"
for limiting maximum outlet temperature.
5. Push sleeve (E) onto the plastic guide (G) by gently
pressing the slotted section (G1) on the plastic guide.
6. Slide the escutcheon (H) over the sleeve (E) and tighten
with screws (H1), see fig. [3].
Do not use excessive force to tighten the screws.
7. Install cover ring (J) onto the valve stem (B) by placing the
stop post (J1) on top of the "Arrow" ↑ (K) and connect the
handle (L), see fig. [4] and [5].
The pressure balancing valve is now ready for use.
If the pressure balancing valve is installed too deep, the
fitting depth can be increased by 1" with an extension set,
Part No. 47 344, see fold-out page II.
Maximum hot water limit setting
The adjustable hot water limit stop (D) is factory set in a
neutral position (0), see fig. [5].
On applications requiring to limit the valve opening from full hot
position, the factory set adjustable hot water limit stop must be
reset as described below.
1. Remove the factory set adjustable hot water limit stop (D),
see fig. [6].
2. Slide the cover ring (J) and the handle (L) onto the valve
stem (B) by placing the stop post (J1) on top of
"Arrow" ↑ (K), see fig. [5] and fold-out page III, fig. [7].
3. Turn the handle (L) counterclockwise until the outlet water
reaches the desired temperature.
4. Pull off handle and read the corresponding number (1 to 10,
see fig. [5]) against the stop post (J1).
5. Push on handle (L) and close the valve by turning the
handle clockwise and pull off handle and cover ring (J).
6. Align the white mark (D1) on the limit stop against the
number (1 to 10, see fig. [5]) you have selected on the dial
and slide the limit stop, see fig. [8].
7. Proceed to item 7 in chapter Installation.
1
English
Note:
The preset maximum temperature will change if the inlet
temperatures change or the setting of the water heater
thermostat is altered.
Winterizing the system
It is recommended that the "pressure balancing cartridge"
be removed from the valve casting if the system is to be shut
off during the winter.
Maintenance
Check, clean and if necessary, replace parts.
Grease with special valve grease.
Pressure balancing cartridge, see figs. [9] to [12].
1. Unscrew handle cap (L1) loosen screw (L2) and remove
handle (L), see fig. [9].
2. Remove cover ring (J).
3. Remove screws (H1) and escutcheon (H) as shown
in fig. [10].
4. Shut off hot and cold water stops (C). The slots are vertical
when the stops are in the off position, see fig. [11].
5. Loosen screws (G2) and detach plastic guide (G) with
sleeve, see fig. [12].
6. Close the valve by turning the stem clockwise. Detach stop
ring (M) and note position.
7. Loosen the four corner screws (N1) and remove valve
cover (N).
8. Pull the pressure balancing cartridge (O) out of the valve
body noting the location of "H" and "C" marking near the
cartridge inlets.
9. Remove the check valve inserts (P).
If the check valves are removed it is important to reinstall
them with the O-ring facing away from the cartridge. If they
are installed incorrectly no water will flow.
The pressure balancing cartridge (O) must be replaced as a
complete unit.
Reassemble in reverse order. Ensure that the hot "H" and
cold "C" markings are on the correct side.
Be sure that the stop ring (M) is installed in the position noted
in item 6.
Replacement parts, see fold-out page II (* = special
accessories)
Care
Instructions for care of this faucet will be found in the Limited