Installation
The projection can be increased by 20mm with an
extension, see Replacement Parts, Prod. no. 07 130.
Reversed connection (hot on right - cold on left).
Replace thermostatic compact cartridge, see Replacement
parts, Prod. no.: 47 885 (1/2").
When using this thermostatic compact cartridge, the Cool
Touch function is no longer available.
Installation of the shower rail
When installing e.g. on plasterboard walls (not solid walls) it
must be assured that an appropriate reinforcement is in place
to ensure sufficient strength.
Adjusting
Temperature adjustment, see page 2 Fig. [1].
Temperature end stop
If the temperature end stop is at 43 °C, insert accompanying
temperature limiter in temperature selection handle,
see Fig. [2].
Operation
The safety stop limits the temperature range to 38 °C.
The 38 °C limit can be overridden by pressing the
button, see page 3.
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
1
Maintenance
Inspect and clean all parts, replace if necessary and
lubricate with special valve grease.
Shut off the hot and cold water supply.
Non-return valve, see page 4.
Drain the fitting before disassembling.
Thermostatic compact cartridge, see page 5.
Readjustment is necessary after every maintenance
operation on the thermostatic compact cartridge
(see Adjusting).
Showers, see page 5.
The function of the SpeedClean nozzles is
guaranteed for a period of five years.
Thanks to the SpeedClean nozzles, which must be
regularly cleaned, limescale deposits on the rose can be
removed by simply rubbing with the fingers.
Replacement parts
( * = special accessories).
Care
For directions on care, refer to the accompanying Care
Instructions.