Télécharger Imprimer la page

Inoksan BYM052 Mode D'emploi page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
1. EXPLANATION
1. The instructions in this manual include
important information regarding the secure
installation, use, cleaning and maintenance of
the machine. Therefore, keep this manual in a
place where the user of the machine or the
technician can reach with ease.
2. The installation of the machine must be
performed according to the instructions of the
producing company by an expert who is
experienced in this topic.
3. The power and water connections of the
machine must be performed in accordance
with the given values in the "Technical
Specifications" chart.
4. Your machine's proper operation and long life
depends absolutely on correct usage, periodic
maintenance, fulfilling the service operations
and your attention.
5. Producer firm does not accept responsibility
of;
any
operation
complying
with
maintenance
or
performed without authorized technicians,
eventual damages that harm people or
properties due to extra reservoir or devices.
2. INSTALLATION INSTRUCTIONS
1. Carry the device to the place of installation
and remove it from its package.
2. Check whether the device is in a solid state. If
there is damage, immediately notify this
situation to your dealer and if you have any
doubt do not operate the device without
having it checked by an expert.
3. Peel away the protective nylon on the device.
If there are material remains left on the
surface, clean them with a convenient
dissolver. (For Example;Henkel-Helios)
If possible, place the device near a water
4.
connection and waste water drain.
3. WATER CONNECTION
1. Connect your device to the city water
normally. However, you can also connect it to
the hot water input in order to save electricity.
2. Perform the connection between the device
and the tap with the provided flexible hose.
3. In order for the device to work correctly, the
input water must be at 7 Fr hardness and min
2 bar, max 4 bar pressure.
4.
Do not use old or used water inlet hose at the new
product.
WARNING:
Drain pipe required to be connected to a
drain at height 50 mm from ground for
performed
without
the
user's
manual,
technical
interventions
base model devices and at max. 700 mm
from the ground for the devices with
pump to maintain a reliable water flow.
 For longer life and efficiency of your device,
attach a lime remover at the water input. Otherwise
the lime scale that will accumulate at the internal
surfaces of the boiler and pump will prevent the
device from working efficiently.
 For your safety, you must turn off the water inlet
tap at the end of the washing program.
4. POWER CONNECTION
1. The installation and power connection of the
device must be performed by authorized
personnel according to the standards.
2. The device needs to be connected to a
network which is consistent with the DIN
VDE 0100 power installment standards.
3. Usage of a H07 RN-F quality 3x2,5mm
profile cable is necessary for the power
connector line.
4. The device needs to be connected to a master
switch (contact distance 3mm or more) and to
a fused isolator.
5. Voltage tolerance ± must not go over % 10.
6. A maximum of 25A fuse must be put to the
device feed line.
7. We recommend the usage of a 30 mA faulty
residual current device.
9
EN
2

Publicité

loading

Ce manuel est également adapté pour: