ergoline Ambition 200 Instructions D'utilisation page 52

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Presets
CAUTION!
Do not set parameter 27 to 0001 unless you really use
the Applied Digital T-Max Manager!
You have to use the parameter edit instructions in the T-
Max documentation to change parameter 27 back to Intelli-
tan protocol. You can not use a CCS-1 or IPI with a timer
using T-Max Protocol.
When parameter 25 is shown, the display will read 0000 for Intellitan pro-
tocol.
– Press
to go to P28 without changing the setting.
To change to T-Max Protocol:
– Press Reset once and then release it. The display will begin to flash.
– Press
unitl 0001 is displayed.
– Press Reset once then release it.
– Next cycle the power to the timer and tanning device off and back on.
The T-Max Protocol is now on.
To turn off this function change parameter 27 back to 0000 using the
parameter edit instructions in the T-Max documentation.
– Press
to go to Parameter 28 (P28).
P28 – Total Operating Cost Accumulator
This parameter tracks total operating costs of the tanning unit based
upon parameter 17, session cost per minute. This parameter is displayed
in dollars and tenths and rolls over at $999.9. The Total Operating Cost
52
Accumulator can be reset to 0 at anytime in order to track or determine
daily, weekly, monthly, quarterly, or annual operating costs.
– Press
to go to P30 without changing the setting.
To reset the total operating cost:
– Press Reset once and then release it. The display will begin to flash.
– Press
until 0000 is displayed.
– Press Reset once then release it.
The total operating cost is now reset to 0 and will begin accumulating
at the next session.
To exit the system
– Press Start/Stop until the display reads 00:00 to exit parameter mode.