PROBLEM
Vacuum recovery is poor.
Little or no solution pressure.
SPECIFICATIONS
MODEL
LENGTH
WIDTH
HEIGHT
WEIGHT
SOLUTION TANK CAPACITY
RECOVERY TANK CAPACITY
SOLUTION PUMP
VACUUM MOTOR
SEALED WATER LIFT
TOTAL POWER CONSUMPTION
POWER CORD
DECIBEL RATING AT OPERATOR'S EAR,
INDOORS ON CARPET
HAND TOOL INCLUDED
8
CAUSE
Vacuum hose cuff is not firmly pushed
onto recovery tank's fitting.
Vacuum filter is clogged.
Recovery tank is not firmly clamped
down onto solution tank. Air leaks
around vacuum gasket.
Vacuum gasket is worn or damaged.
Spray tip filter on hand tool is clogged. Remove spray tip to get access to
1000
533 mm (21 in)
197 mm (7.75 in)
445 mm (17.5 in)
8.2 Kg (18 lbs)
7.57 L (2 gal)
5.67 L (1.5 gal)
120 VAC, 2.1 kPa (30 psi), 1.25A, 150W
220 VAC, 2.1 kPa (30 psi), .75A, 165W
230 VAC, 2.1 kPa (30 psi), .75A, 173W
240 VAC, 2.1 kPa (30 psi), .75A, 180W
120 VAC, 1.12 HP, 7A, 840W, 2 stage, 80 cfm
220 VAC, 1.12 HP, 3.5A, 770W, 2 stage, 84.5 cfm
230 VAC, 1.12 HP, 3.5A, 805W, 2 stage, 84.5 cfm
240 VAC, 1.12 HP, 3.5A, 840W, 2 stage, 84.5 cfm
1800 mm (71 in) 120V
1968 mm (77.5 in ) 220V/230V/240V
120VAC, 8.25A, 990 W
220 VAC, 4.1A, 902 W
230 VAC, 4.1A, 943 W
240 VAC, 4.1A, 984 W
<78 dB(A)
102 mm (4 in) path, 1Jet, .95 LPM (.25 GPM), 2.4M (8 ft) Vacuum
and Solution Hoses.
Home Find... Go To..
SOLUTION
Push vacuum hose cuff all the way
onto recovery tank fitting.
Remove and clean filter.
Clamp both latches down to form a
tight seal between tanks.
Replace gasket.
filter. Remove and clean filter.
7.6 M (25 ft) 18/3--120V
7.6 M (25 ft) 3X1.0MM 2X8M--220V/230V/240V