PARAMETER CHECKING AND ADUSTMENT

Parameter list

Some system parameters can be checked and adjusted by the controller. Below is the parameter
list:
Parameter
No.
0
Tank water setting temp.
Water temperature
1
gap to restart
2
E-heater off tank water temp
3
E-heater delay time
4
Week disinfection temperature
5
High temp disinfection time
6
Defrosting period
7
Defrosting entry coil temp.
8
Defrosting exit coil temp.
9
Max defrosting cycle period
Electronic expansion valve
10
adjustment
11
Target over-heat degree
Steps of manually adjusting the
12
electronic expansion valve
Disinfection
13
adjusting
14
Parameter of solar water pump
15
Solar water pump star return
difference
16
High temp disinfection
frequency
17
Temperature setting
method
18
Set temperature when light
source is present (PV is on)
19
Set temperature when no light
source (PV is alternating)
A
Inlet water temp.
sensor detect range
Outlet water temp.
B
sensor detect range
Description
start
up time 0~23
Range
Default
10 ~ 70°C 50°C
2 ~ 15°C
5°C
10 ~ 85°C 55°C
0 ~ 90min 6
50 ~ 70°C 70°C
0 ~ 90 min 30 min
30~90 min 45 min
-30 ~ 0°C
-7°C
2 ~ 30°C
13°C
1 ~ 12 min 8 min
0/1
1
-9 ~ 9°C
5°C
10 ~ 50
35 step Adjustable
step
23
0/1
0
2-20℃
10
7-28day
7
0/1
1
10 ~ 70°C 60
10 ~ 70°C 50
Actual testing value. Error code P1
will be shown in case of a
-9 ~ 99°C
malfunction
Actual testing value. Error code P2 will
-9 ~ 99°C
be shown in case of a malfunction
Remarks
Adjustable
Adjustable
Adjustable
t * 5 min
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable (0-manual,
1-auto)
Adjustable
Adjustable(hour)
Adjustable(
0
without
water pump,1with water
pump)
Adjustable
Adjustable
60