Troubleshooting
If the inverter doesn't function properly, there can be several causes:
1) Poor contact: clean contact parts thoroughly
2) Inverter has no power: check car fuse, replace damaged fuse, check connection of
wires
3) Fuse is blown: the fuse is located in the DC (cigarette) plug. Replace the fuse with a
similar fuse of equivalent value
4) AC output shutdown caused by overload: make sure the continuous load of the
attached appliances does not exceed 1000 Watts
5) AC output shutdown caused by overheating: under heavy loads for extended periods
of time, the inverter will shutdown the output to prevent damage from over heating. If
this happens, please proceed as below:
(A) Switch off the power switch of the inverter
(B) Decrease load of the machine i.e. disconnect some of the appliances or wait
until this inverter cools down.
(C) Switch on the power switch of the inverter.
6) Low-battery shutdown: recharge your battery and resume operation.
Caution!
Always place the inverter in an environment that is:
1. Well ventilated
2. Not exposed to direct sunlight or heat
3. Out of reach from children
4. Away from water, moisture, oil or grease
5. Away from any inflammable substances