venTIlaTIon

Risk of indoor air pollution. Use heater only in well ventilated areas. Always provide a fresh air opening in
the heated space of at least three square feet (2,800 sq. cm) for each 00,000 BTU/Hr. of heater output.
Provide a larger opening if more heaters are being used. As an example, an MH-025-0M0 heater will
require:
a two-car garage door open 6 inches, or
a single car garage open 9 inches, or
two thirty two inch wide windows open fifteen inches.

To sTaRT The heaTeR

. Fill the tank with kerosene until fuel gauge points to "F".
2. Be sure fuel cap is secure.
3. Plug power cord into three prong, grounded extension cord and plug extension cord into three prong
20V grounded outlet.
The extension cord should be at least six feet long.
Minimum extension cord wire size requirements are as
follows:
6 to 10 feet (1.8 to 3 meters), use 18 AWG wire.
11 to 100 feet (3.4 to 30.4 meters), use 16 AWG wire.
101 to 200 feet (30.8 to 61 meters), use 14 AWG
wire.
4. Turn thermostat control knob to desired temperature setting.
The setting range is from 40° F to 0° F. Push the Power
switch to the "ON" position. The power indicator lamp
and room temperature display (MH-025-0M0/MH-075-
0M0/MH-025-0M0 only) will light and the heater will
start.
NOTE: The room temperature display (Mh-0125-0M10/Mh-0175-
0M10/Mh-0215-0M10 only) will indicate the following:
When temperature is less than 0° F, display says
"LO".
When temperature is above 99° F, display says "HI".
Between 0° and 99° F display shows actual tempera-
ture.
If the heater does not fire, the thermostat may be set too
low. Turn the Control Knob to a higher setting until heater
fires. If the heater still does not start, push Power Switch
to "OFF", then back to "ON". If heater still does not fire,
see Troubleshooting Guide.
NOTE: The electrical components of this heater are protected by a fuse mounted in the PC board. If the heater fails to fire,
check this fuse first, and replace if necessary. Also check the power source to be sure that the proper voltage is being
provided to the heater.

To sToP The heaTeR

Simply turn the Power switch to "OFF" position and unplug the Power Cord.

To ResTaRT The heaTeR

. Wait ten seconds after shutting off heater.
2. Turn the Power Switch to "ON" position.
3. Be sure to follow all starting procedure precautions.
Kerosene Portable Heaters Manual
*Always follow manufacturer instructions*
OPERATION
*AAA Rent-All 225-291-1356*
Lamp
Room Temperature
Display
Thermostat Control Knob
Power Switch
Power Switch
3