Refi t the heater to the wall fi xing bracket (i.e. follow steps as
in Fig. 4 a, b, c and d) and rotate the bottom fi xing bracket
down again and use the screw provided to permanently fi x the
heater in place.
The heater should not be connected until the instruction leafl et
is read fully.
Recessed Installation
Please note that this appliance can also be wall-mounted so
that it is recessed. This can be installed in a large fi replace
opening or a purpose built wall. See Table 1 for size of recess
required and hole fi xing dimensions and Fig. 5a. This fi replace
insert does NOT require venting.
In order to ensure it's future safety in use, it is essential
that this fi re is securely fi xed to the wall.
IT IS IMPORTANT THAT THE FIXING DEVICE CHOSEN
IS APPROPRIATE TO THE WALL MATERIAL TO WHICH
THE FIRE IS BEING FIXED. SOME MODERN INTERNAL
BUILDING MATERIALS ARE VERY LOW DENSITY BLOCK
AND REQUIRE SPECIALIZED FIXING DEVICES TO
PROVIDE A SAFE,SECURE INSTALLATION.
The installation of this fi re should be carried out by a competent
person. If in doubt please consult your local builder.
This section provides step by step instructions for selecting
a location and preparing the site to install the fi replace into
the following:
Existing Fireplace
1. Make sure that the fi re is located on a fl at surface.
2. Seal all draughts and vents to prevent chimney debris
from falling onto the Fireplace Insert. Do not install into an
existing fi replace that is prone to dampness.
3. Remove the fi re front panel by following the steps as
outlined in 'Lamp Replacement' sections.
4. Locate the 4 fi xing holes, position the fi re accordingly, and
fi rmly fi x the appliance to the wall using the appropriate
screws - see Fig. 5a.
5. Replace the front panel.
New Support Structure Construction
When planning where to position your purpose built support
structure the following steps must be observed:
1. Place the fi re in the desired location to see how it will look
in the room.
2. Mark the desired location for the new support structure
in the room and store the fi re in a safe, dry and dust free
location.
3. Using timber studs to support the fi re, devise and construct
a suitable means of supporting the product within the wall
partition and provide electrical power for the fi re to be HARD
wired. For recommended sizes of height, width and depth
of opening for recess and hole fi xing dimensions for each
model - see Table 1 and Fig. 5a.
4. When the structure is complete, remove the front panel
of the fi re by following the steps as outlined in 'Lamp
Replacement' sections.
5. Locate the 4 fi xing holes, position the fi re accordingly, and
fi rmly fi x using the appropriate screws.
6. Replace the front panel.
A
X
1160
1143
NOTE: The appliance should be HARD wired to an electrical
power outlet when placed in a recessed installation.
Please consult a qualifi ed electrician for appropriate wiring
requirements.
Manual Operation
The switches are located at the bottom right side of the
appliance - see Fig. 6.
Remote Operation
The standby switch (S1) must fi rst be turned 'ON'.
Note: It takes some time for the receiver to respond to the
transmitter. DO NOT PRESS the buttons more than once within
two seconds for correct operation.
Manual & Remote Operation
Setting
Flame Effect
Press the 'I' button X 1 (Switch 3)
Flame Effect & 1kw Heat
Press the 'I' button X 2 (Switch 3)
Flame Effect & 2kw Heat
Press the 'I' button X 3 (Switch 3)
The Standby switch must fi rst be turned 'ON' to operate the
appliance manually or by remote control.
Note: It takes some time for the receiver to respond to the
transmitter. DO NOT PRESS the buttons more than once within
two seconds for correct operation.
To go to the previous settings press the O button.
Pressing the O button on the remote turns off the appliance. To
turn the appliance back On press the I button - see Fig. 8.
To increase or decrease the brightness of the fl ames, use the
dimmer button or the
button on the Remote Control.
To turn off the power the Standby Switch must be turned
'OFF'.
TABLE 1
Y
Z
520
146
Operation
Setting
Top Neon
Middle Neon
Bottom Neon