Technical information sheet
• 12 to 18 : sequences. 12.Fast gradient | 13.Slow rainbow | 14.Colours parade | 15.Techno rhythm | 16.Blue variations |
17.Random parade | 18. Ramdom colours
The voltage drop in the supply cable of the Mid-
BRiO & Mid-BRiO LT M24 & X24 cable should
be limited in order to comply with the applicable
standards and ensure optimal illumination.
Follow the table opposite (one projector per ca-
ble)

8. Projector Protection

Independent protection is necessary for each Mid-BRiO & Mid-BRiO LT M24 & X24 (even if several projectors are connected
to the same transformer). Protection must be ensured in the secondary of the transformer using fuses or breakers at 2A (M24LT
& X24LT) or 4A (M24 & X24). The cable cross-section must be adapted accordingly.
A. Declaration of conformity
declares that the Mid-BRiO & Mid-BRiO LT M24 & X24 product meets the safety and elec-
tromagnetic compatibility requirements of European directives 2014/35/EU and 2014/30/EU.
Date of sale: . . . . . . . . . . . . . . . . . . . . . . . Batch N°: . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mid-BRiO & Mid-BRiO LT M24 & X24
2,5 mm²
4 mm²
Max. length
15 (LT)
25 (LT)
(m)
7 (M/X24)
12 (M/X24)
Distributor's stamp
CROSS-SECTION (mm²)
6 mm²
40 (LT)
60 (LT)
20 (M/X24)
30 (M/X24)
Emmanuel Baret
Marseille, on 29/01/2021
v1.0EN
4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Midbrio lt m24Midbrio lt x24Pk10r400Pk10r401Pk10r402Pk10r404 ... Afficher tout

Table des Matières