Technical information sheet
3. Technical specifications
Dimensions
Installation
Power supply
Power consumption
Max. luminous flux
LED type
Protection rating
4. Installation
4.1. Connection to electricity
Installation of this project involves a hazard of electric shocks. We strongly recommend you
contract a professional installer. An installation error can put you in danger and may irre-
versibly damage the product and the equipment connected to it.In compliance with the NF C
15-100 standard, pool lights installed in Volume 0 must always be powered by VLSV (Very low
safety voltage). Always cut off the power upstream before handling the electrical installation.
Risk of electric shock. Only connect to a circuit which is protected by a ground fault circuit
breaker . If you are not sure if these types of device are fitted, contact a qualified electrician.
Mid-BRiO & Mid-BRiO LT M24 & X24
In the CCEI universal side exit mini-recess PF10R261
In the CCEI universal axial exit mini-recess PF10R262
24W (Version X24 RGBW) - 1800 lm (depending on the colour)
12W - Versions M24 LT and M24K LT - 1200 lm
12W (Version X24 LT) - 900 lm (depending on the colour)
Take into account the total power for all lighting to determine which 12V (100 /
PK10R400 (M24)
PK10R401 (M24K)
PK10R402 (X24)
PK10R404 (M24 LT)
PK10R405 (M24K LT)
PK10R406 (X24 LT)
It is imperative to connect to the electricity supply in a dry
environment, in a sealed connection box of which the cable
glands must be tight to prevent any water ingress.
Ø70 mm / depth 80 mm
In a standard 1.5" brush socket
Voltage: 12 V ~ (AC) / Frequency: 50Hz/60Hz
24W - Versions M24 and M24K - 2400 lm
300VA) transformer to use.
18 Power LEDs cold white (~6500°K)
18 Power LEDs warm white (~2700°K)
24 Power LEDs monochrome
9 Power LEDs cold white (~6500°K)
9 Power LEDs warm white (~2700°K)
12 Power LEDs monochrome
Risk group 1 (low risk) as per IEC62471:2006
v1.0EN
(6R/6G/6B/6W)
(3R/3G/3B/3W)
IP-68
2